| General |
| Model | Wall mounting, EMC |
| Material | Plastic |
| Colour | RAL 7035 |
| Scope of delivery | Complete ready-to-install unit, including EMI filter mat |
| Fan | Axial, split-pole motor |
| Airflow free-blowing (with filter) | At 50 Hz: 100 m³/h, At 60 Hz: 115 m³/h |
| Airflow with associated exhaust filter including felt filter | At 50 Hz: 75 m³/h, At 60 Hz: 86 m³/h |
| Rated operating voltage | 115 V, 1~, 50 Hz/60 Hz |
| Rated power Pel | At 50 Hz: 15.4 W, at 60 Hz: 15.8 W |
| Rated current max. | At 50 Hz: 0.2 A, At 60 Hz: 0.21 A |
| Width | 204 mm |
| Height | 204 mm |
| Depth | 105 mm |
| Built-in depth | 84 mm |
| Mounting cutout | Cutout width: 177 mm, cutout height: 177 mm |
| Degree of protection IP according to IEC 60 529 | IP 54 with felt filter, IP 56 with felt filter and spray hood |
| NEMA degree of protection | Type 12 with felt filter, Type 3, 3R, 4, 4X with felt filter and spray shield |
| Fuse | Circuit breaker/fuse: 2 A |
| Note | To improve energy efficiency and increase device lifespan, use of temperature controllers or indicators is recommended. |
| Operating temperature range | -15 °C...55 °C |
| Storage temperature range | -30 °C...70 °C |
| Sound pressure level | At 50 Hz: 51 dB(A), At 60 Hz: 54 dB(A) |
The Rittal SK 3239.810 is an
EMV filter fan for
enclosure climate control, designed for
wall mounting in industrial environments. The device provides controlled ventilation of enclosures to regulate internal temperature and extend the service life of installed electronic components. It is designed as a
fully ready-to-install unit, including an
EMV filter mat that reduces electromagnetic interference and meets requirement class 2 according to EN 61587-3. The
plastic enclosures in
RAL 7035 are robust and suitable for use in industrial installations.
Applications
The filter fan is designed for use in enclosures where continuous, dust- and moisture-reduced ventilation is required. It is particularly suitable for applications in manufacturing, energy supply, or automation technology, where EMV protection and uniform air circulation are important. The
tool-free mounting and
optimized snap hooks enable quick installation on the enclosure wall. The
mounting cutout measures 177 mm in width and height, precisely defining the installation position within the enclosure.
Functions and Equipment in Detail
The fan features an
axial single-phase motor, ensuring reliable and quiet air movement. The
free-blowing air performance is 100 m³/h at 50 Hz and 115 m³/h at 60 Hz, while the air performance drops to 75 m³/h (50 Hz) or 86 m³/h (60 Hz) when using an additional outlet filter. These values account for the resistance of the nonwoven filter, which retains dust and particles. The
diagonal fan technology ensures higher pressure stability and more uniform ventilation of the enclosure, improving cooling efficiency. The
sound pressure level is 51 dB(A) (50 Hz) and 54 dB(A) (60 Hz), representing acceptable noise emissions for industrial applications.
Technology Explained Simply
The
rated operating voltage is 115 V, 1~, designed for frequencies of 50 Hz and 60 Hz, enabling worldwide use. The
rated power is 15.4 W (50 Hz) or 15.8 W (60 Hz), representing a low energy consumption class. The
maximum rated current is 0.2 A (50 Hz) or 0.21 A (60 Hz). The
fuse is rated at 2 A to protect the fan from overloads. The
installation depth is 84 mm, allowing the fan to be installed in enclosures with sufficient rear space. The
dimensions of the device are 204 mm (width) × 204 mm (height) × 105 mm (depth).
Compatibility and Accessories
The fan is equipped with a
nonwoven filter that retains dust and particles. For higher protection class, an
outlet filter EMV in RAL 7035 can be combined to reduce airflow but enhance filtration effectiveness. A
stainless steel spray hood allows increasing the protection rating to IP 56 and meets NEMA classes Type 3, 3R, 4, and 4X. Additionally,
thermostats,
speed controllers, or
digital temperature displays can be used to improve energy efficiency and extend the fan’s service life. The use of a
hygrostat is also possible to monitor humidity inside the enclosure.
Mounting and Installation
Mounting is tool-free on the enclosure wall. The optimized snap hooks and the new opening mechanism on the louver grille facilitate filter replacement. The installation position is defined by the standard mounting cutout of 177 mm × 177 mm. The installation depth of 84 mm must be considered in the enclosure to ensure secure mounting.
Operational Advantages
The fan provides reliable, interference-free ventilation with integrated EMV shielding. The
protection rating IP 54 (with nonwoven filter) or
IP 56 (with nonwoven filter and spray hood) protects against dust and splashing water. The
operating temperature range of -15 °C to 55 °C allows use in a wide range of environments. The
storage temperature range of -30 °C to 70 °C ensures storage capability under extreme conditions. The combination of low energy consumption, long service life, and easy maintenance makes the fan an efficient solution for enclosure climate control.