| Technical data |
| System compatibility | VARES-3000 |
| Dimensions (W x H x D) | 107 x 20 x 100 mm |
The
Bus-Extension Slave Module PBE-285A from
RCS Audio-Systems is a digital expansion module for the
VARES-3000 system. It serves to extend the I²C bus originating from the Control Center PSS-224 C, enabling the integration of additional components into existing emergency warning systems. The module operates as a slave device and requires the presence of the master module PBE-185 A in the Control Center to maintain communication over the I²C bus. The connection is made via a cable with a maximum length of 20 meters, allowing flexible placement of the expansion unit.
Applications
The PBE-285A is specifically designed for expanding emergency warning systems in the field of
sound technology. It is used when the number of devices connected to the Control Center exceeds the physical limits of the I²C bus or when spatial separation between the Control Center and peripheral devices is required. Typical application scenarios include large building complexes, industrial facilities, or public institutions, where signal transmission over long distances must be ensured without signal loss.
Functions and Equipment in Detail
The module functions as a
digital slave module in the I²C network and is responsible for receiving data packets from the master module PBE-185 A and forwarding them to connected peripheral devices. It is not capable of generating or processing data independently, but serves exclusively as a bridge in the communication network. Digital signal transmission ensures high data integrity and minimizes interference that could occur with analog transmission. The maximum cable length of 20 meters allows flexible installation without compromising signal quality.
Technology Explained Simply
The I²C bus (Inter-Integrated Circuit) is a serial bus system used for communication between integrated circuits. In this system, the Control Center PSS-224 C acts as the master, while the PBE-285A functions as a slave. Communication takes place over two lines: one for data transmission (SDA) and one for clock signals (SCL). The PBE-285A receives data from the master and forwards it to downstream devices, thereby extending the bus range. Digital transmission technology ensures that signals remain stable even over long distances.
Compatibility and Accessories
The module is exclusively compatible with the
VARES-3000 system and requires the master module
PBE-185 A in the Control Center PSS-224 C. It is intended for use with the expansion module
PEU-056 B, which is also part of the VARES-3000 system. The connection is made via a separate cable, with a maximum length of 20 meters.
Installation and Mounting
Installation is carried out by connecting the module to the I²C bus network via the connection cable. The module is housed in a compact enclosure with dimensions of 107 x 20 x 100 mm (W x H x D), allowing placement in standard 48,3 cm ( 19 inch ) racks or at wall mounting points. No special tools or additional power supply are required, as the module is powered via the I²C bus.
The module dimensions are 107 mm (width) x 20 mm (height) x 100 mm (depth). This compactness allows flexible placement in existing installations without additional space requirements.
Operational Advantages
By extending the I²C bus, the PBE-285A enables the integration of additional devices into existing emergency warning systems without requiring reconfiguration or expansion of the Control Center. Digital signal transmission ensures high reliability and minimizes error sources. The maximum cable length of 20 meters provides flexibility in planning the system architecture. The module is specifically developed for use in professional sound systems, ensuring stable and maintenance-friendly integration into existing infrastructures.
Dimensions and Design
The module has a compact design with dimensions of 107 mm (width) x 20 mm (height) x 100 mm (depth). These dimensions allow easy mounting in standard 48,3 cm ( 19 inch ) racks or on wall fixtures. The low height of 20 mm makes it particularly suitable for installations where space is limited.
System Affiliation
The module is part of the
VARES-3000 system from RCS Audio-Systems and is intended exclusively for use within this system. It is not compatible with other systems or manufacturers. System affiliation is crucial for correct operation, as communication protocols and signal transmission are specifically designed for the VARES-3000 system.
Compatibility with Other Modules
The module is specifically designed for use with the expansion module
PEU-056 B, which is also part of the VARES-3000 system. The connection is made via a separate cable, with a maximum length of 20 meters.
Function in the System
The PBE-285A functions as a
slave module in the I²C network and is responsible for receiving data packets from the master module PBE-185 A and forwarding them to connected peripheral devices. It is not capable of generating or processing data independently, but serves exclusively as a bridge in the communication network. Digital signal transmission ensures high data integrity and minimizes interference that could occur with analog transmission. The maximum cable length of 20 meters allows flexible installation without compromising signal quality.
System Integration
Integration of the module into the VARES-3000 system is achieved by connecting it to the master module PBE-185 A in the Control Center PSS-224 C. Communication takes place over the I²C bus, with the module functioning as a slave device. Digital signal transmission ensures that signals remain stable even over long distances. The maximum cable length of 20 meters provides flexibility in planning the system architecture. The module is specifically developed for use in professional sound systems, ensuring stable and maintenance-friendly integration into existing infrastructures.