Phoenix Contact 1014420, EAN: 4055626492179

Phoenix Contact 1014420 HC-BB18-I-PT-M contact insert

Industrial Material > Industrial Connectors > Industrial Connectors

Phoenix Contact 1014420 HC-BB18-I-PT-M contact insert

Lieske Part No. 1592328
Mfg Part No 1014420
EAN-Code 4055626492179
Manufacturer Phoenix Contact
Here only 21,38 EUR
25,44 EUR incl. VAT

Further information for Phoenix Contact 1014420 HC-BB18-I-PT-M contact insert

General
Number of poles18+PE
Construction sizeB10
Power contacts18
Control contacts0
Number of connections per pole1
Form of contactPin
Connection systemPush-in connection
Operating voltage500 V
Current carrying capacity16 A
Connection cross section0.5 to 2.5 mm²
ApplicationPerformance
The HC-BB18-I-PT-M contact insert from Phoenix Contact is a component for industrial connectors, specifically designed for use in power circuits. It features a pole count of 18+PE and is manufactured in size B10. The construction includes 18 power contacts and no control contacts, with each pole providing one connection point. The contacts are designed as pins and support the push-in connection, enabling quick and secure connection without additional tools. The maximum operating voltage is 500 V, and the permissible current rating is 16 A. The connection cross-sections range from 0.5 mm² to 2.5 mm², making it suitable for a wide range of cable cross-sections in industrial applications.

Applications
This contact insert is primarily intended for use in power circuits, for example in automation technology, machine and plant construction, and electrical installation. It is suitable for applications requiring a reliable and robust electrical connection, particularly in environments with high mechanical stress or industrial operating conditions. The size B10 enables compact mounting in connector systems designed for use in enclosures or on printed circuit boards.

Functions and Features in Detail
The use of push-in technology enables quick and tool-free connection of cables. The contacts are designed as pins, ensuring a secure mechanical connection. The number of connections per pole is one, allowing for clear assignment of cables. The maximum current load of 16 A and voltage of 500 V make it suitable for power circuits where high electrical loads need to be transmitted. The permissible cross-sections of 0.5 mm² to 2.5 mm² cover a broad range of industrial applications.

Technology Explained Simply
The push-in connection works via a spring-loaded clamp that automatically secures the cable upon insertion. This reduces assembly time and minimizes error sources. The pin contact design ensures a stable electrical connection that remains secure even under mechanical stress. The size B10 is a standard format in the industry, offering high compatibility with other components of Phoenix Contact’s HEAVYCON system. The designation 18+PE means that 18 poles are designated for power contacts, with the PE pole serving as the protective conductor (earth).

Compatibility and Accessories
The contact insert is part of Phoenix Contact’s HEAVYCON system and can be combined with various accessories to extend functionality. These include coding elements such as the HC-CST or HC-CBU, which enable unique identification of connectors. Cable strain relief clamps such as the HC-B-ZS provide mechanical relief for cables. Mounting frames such as the HC-CIF-B10-HFWL-PL or HC-CIF-B06-24-BFAFL-PL facilitate installation in enclosures. Crimping tools such as the CF CRIMPHANDY series or crimping tools such as CRIMPFOX models can be used for cable preparation, although the push-in connection itself does not require crimping.

Mounting and Installation
Mounting is performed by inserting the contact insert into the corresponding connector of size B10. Cables are inserted directly into the push-in contacts, ensuring correct pole assignment. The use of mounting materials such as HC-B-PES or coding profile CP-HC-S can simplify installation in complex systems. Installation typically takes place in enclosures or on printed circuit boards, with mechanical stability ensured by the size B10 and pin contact design.

Advantages in Operation
The use of the HC-BB18-I-PT-M contact insert provides high operational safety due to its robust construction and push-in technology. Tool-free assembly reduces installation time and minimizes errors. Clear pole assignment and compatibility with the HEAVYCON system simplify maintenance and replacement. The electrical ratings of 500 V and 16 A, along with the cross-section coverage of 0.5 mm² to 2.5 mm², make it flexible for use in various industrial applications.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1592328
qrcode für Phoenix Contact 1014420 HC-BB18-I-PT-M contact insert