The IMC-101-M-ST-T is a rugged industrial-grade media converter that enables the conversion of 10/100BaseT(X) copper Ethernet to 100BaseFX fiber via a multi-mode ST connector. Designed for harsh environments, it supports extreme temperature ranges and is certified for use in hazardous areas.
With its extended operating temperature range of -40 to 75°C, robust metal housing, and built-in 1.5 kV magnetic isolation, the IMC-101-M-ST-T ensures secure and stable data transmission in mission-critical applications. It is also compliant with ATEX and UL/cUL safety standards, making it ideal for demanding field installations.
Technical Specifications (English):
Ethernet Interface:
- 1x 10/100BaseT(X) RJ45 port
- 1x 100BaseFX multi-mode ST port
- Magnetic Isolation: 1.5 kV (built-in)
Power Parameters:
- Input Voltage: 12 to 45 VDC
- Input Current: 200 mA
- Power Consumption: 200 mA @ 12 to 45 VDC
- Overload Current Protection: Supported
- Power Connector: Terminal block
Physical Characteristics:
- Housing: Metal
- IP Rating: IP30
- Dimensions: 53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in)
- Weight: 630 g (1.39 lb)
- Installation: DIN-rail mounting
Environmental Limits:
- Operating Temperature: -40 to 75°C (-40 to 167°F)
- Storage Temperature: -40 to 85°C (-40 to 185°F)
- Ambient Humidity: 5 to 95% (non-condensing)
Standards and Certifications:
- EMC: EN 55032/24
- EMI: CISPR 32, FCC Part 15B Class A
- EMS:
- ESD: Contact 6 kV, Air 8 kV (IEC 61000-4-2)
- RS: 10 V/m (IEC 61000-4-3)
- EFT: Power 2 kV, Signal 1 kV (IEC 61000-4-4)
- Surge: Power 2 kV, Signal 1 kV (IEC 61000-4-5)
- CS: 3 V/m (IEC 61000-4-6)
- PFMF: IEC 61000-4-8
- Voltage Dips: IEC 61000-4-11
- Safety: EN 60950-1, UL 60950-1
- Vibration: IEC 60068-2-6
- Environmental Testing: IEC 60068-2-1/-2/-3
- Hazardous Locations: ATEX Zone 2, UL/cUL Class I Division 2 Groups A/B/C/D
- Maritime Approval: DNV
MTBF:
- Time: 401,000 hours
- Standard: MIL-HDBK-217F
Warranty:
- Period: 5 years
- Details: www.moxa.com/warranty