Further information for Moxa EDS-316-T switch 16x 10/100BaseT(X) -40 to 75°C
General
Number of Ethernet ports
16 Stück
Relay operating voltage
24 VDC
Auto MDI/MDI-X
The Moxa EDS-316-T is an unmanaged Ethernet switch with 16 ports, specifically developed for use in industrial environments. It serves as a cost-efficient solution for networking machines, controls, and sensors in production facilities, where high reliability and operational safety are required. The switch is designed for use in harsh industrial environments, including hazardous areas according to the standards Class I Div. 2 and ATEX Zone 2, making it suitable for applications in the chemical, energy, or mining industries. The devices undergo a 100% burn-in test to ensure reliability in critical automation systems.
Applications
The EDS-316-T is suitable for industrial networks where simple, maintenance-free networking of end devices is required. It is commonly used in production lines, manufacturing automation, energy supply, or transportation technology, where devices operate under extreme environmental conditions. The wide operating temperature range of -40 to 75 °C enables use in climatically demanding areas, such as outdoor installations, cooling systems, or hot production halls.
Functions and Features in Detail
The switch features 16 10/100BaseT(X) ports with RJ45 connectors, which automatically set the transmission speed (auto-negotiation) and duplex mode (Full/Half). The Auto MDI/MDI-X function allows direct connection to other devices without additional crossover cables. An integrated relay output signal with a current capacity of 1 A at 24 VDC serves as a warning function in case of power failure or a defective network port. This enables quick fault detection and response in the network. Additionally, the switch offers protection against broadcast storms to prevent network overloads.
Technology Explained Simply
The unmanaged architecture means that the switch does not require configuration via a web interface or CLI. It operates automatically and is therefore ideal for applications where no network administration is required. The operating temperature range of -40 to 75 °C makes it robust against extreme climatic conditions. The FCC, UL, and CE certification confirms compliance with international safety and EMC regulations. The devices are designed for mounting on a DIN rail or in a distribution box, enabling flexible installation in existing systems.
Compatibility and Accessories
The EDS-316-T is part of the EDS-316 series and can be combined with other models in the series to build larger networks. As an alternative, the unmanaged EDS-316 without the -T designation is available, featuring a standard operating temperature range of -10 to 60 °C.
Mounting and Installation
Mounting is simple on a DIN rail or in a distribution box. No special tools or additional components are required. Installation is direct into existing industrial networks, with automatic functions such as auto-negotiation and Auto MDI/MDI-X simplifying configuration.
Operational Advantages
The EDS-316-T offers high operational safety through the integrated warning function for power failure or port faults. The wide operating temperature range and certification for hazardous areas increase application safety. The unmanaged architecture reduces maintenance effort and the complexity of network management. The devices are designed for continuous operation in industrial applications and require no special maintenance.