Further information for Moeller Electric DE1-129D6FN-N20N - EATON speed starters mains 1ph 3ph motor 230V 9 6A 174 332
Speed starter, type code: DE1, rated operating voltage: Ue = 230 V AC, 1-phase, 240 V AC, 1-phase, output voltage at Ue: U2 = 230 V AC, 3-phase, 240 V AC, 3-phase, mains voltage (50/60Hz): ULN = 200 (-10%) - 240 (+10%) V, rated operating current at 150% overload: Ie = 9.6 A, note: rated operating current at a switching frequency of 16 kHz and an ambient temperature of +50 °C, note: overload cycle for 60 s every 600 s, assigned motor power note: for normal four-pole, internally and externally ventilated three-phase asynchronous motors with 1500 min-1 at 50 Hz or 1800 min-1 at 60 Hz, overload cycle for 60 s every 600 s, at 230 V, 50 Hz, assigned motor power 150% overload: P = 2.2 kW, 150% overload: IM = 8.7 A, assigned motor power note: at 220 - 240 V, 60 Hz, assigned motor power 150% overload: P = 3 HP, assigned motor power 150% overload: IM = 9.6 A, protection class: IP20/NEMA 0, interface/fieldbus (built-in): OP-Bus (RS485)/Modbus RTU, equipment: radio interference filter, size: FS2, standards and regulations: general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, safety requirements: IEC/EN 61800-5-1