MFA 2001

MFA 2001

Measurement > Ammeters

MFA 2001

Lieske Part No. 217276
Mfg Part No MFA 2001
EAN-Code
Manufacturer
Here only 157,32 EUR
187,21 EUR incl. VAT

Further information for MFA 2001

The multi-function displays MFA 1001 and MFA 2001 universal electronic measuring instruments for the measurement and
monitoring of all important variables in the three-phase mains.
The LC display with backlight (MFA 2001) provides a safe and glare-free reading even from a distance.
A user-friendly operation and the direct indication of the functions of all measured values ​​characterize this multi-function displays from.
using integrated an hour meter. using the MFA in 2001 and the advanced features to the basic version next are a phase failure relay function further parameters and additions to the network analysis. Various data interfaces are optionally available measurement data MFA 2001














Voltage
  • Measurement voltage U (L1-N, L2-N, L3-N)
  • reading voltage U (L1-L2, L2-L3, L3-L1)
  • Min. Voltage U (L1-N, L2-N, L3-N) (since last reset)
  • Min. Voltage U (L1-L2, L2-L3, L3-L1) (since last reset)

Current
  • Current I (L1, L2, L3)
  • mean current I (according to the integration time)
  • maximum current I (since last reset)
  • Maximum current I from the mean (since last reset)

Frequency
- Frequency f (L1, L2, L3)

Performance
  • Active power P, the actual value (L1, L2, L3)
  • Active power P, mean (according to the integration time)
  • Active power P, maximum value (since last reset)
  • reactive power Q, current value (L1, L2, L3)
  • reactive power Q, mean (according to the integration time)
  • reactive power Q, maximum value (since last reset)
  • Power factor cos f (L1, L2, L3)
  • Active power P, sum total power
  • reactive power Q, sum total power
  • power factor cos f, total power
  • active power P, total average total power
  • reactive power Q, sum of average total power
  • power factor cos f, average total net

Hours
- Operating hours h

Working
  • Active work Wh (reference)
  • Reactive varh (inductive) phase failure - phase failure function (L1-N, L2-N, L3-N) - phase failure function (L1-L2, L2-L3, L3-L1) - LCD backlight






Input
  • Power input A standard 5
  • 1 A power input optional
  • Direct Input Current 30 (50) A option
  • input voltage 400 V phase to phase
  • Input voltage 110 V phase to phase optional

Outputs
  • Analog output 0/4-20 mA optional
  • RS 485 interface for PC software including readout optional
  • optional Profibus DP V0
  • Limit 2 contacts

more options
  • Separate auxiliary voltage 230 V AC optional
  • separate auxiliary voltage 24 V DC optional
  • DIN rail mounting option
  • Interface converter RS 485 / RS 232 optional
  • Interface converter RS 485 / USB optional Key Features display the average current and the averaged maximum current (bimetal / pointer - function ) CT connection 1 A or 5 A -definable transformer ratios Faster, safer connection by screw terminals (for cable diameter up to 4 mm2) In beschaltetem limit selectable output: pulse output or alarm output No separate power supply is required











Specifications
Front panel dimensions 96 x 96 mm
panel cutout 91 x 91 mm
Protection class IP 52 front side
IP 65 (optional) Operating temperature range -10 ° C .... +55 ° C voltage input 340-475 V phase - phase 196-275 V Phase - N Current input 0 5 ... A (1 A) Frequency 45 - 65 Hz
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/217276
qrcode für MFA 2001