| General |
| Panel cutout | 91 x 91 mm |
| Degree of protection | IP 52 front |
| Degree of protection optional | IP 65 |
| Operating temperature range | -10 °C |
| Voltage input | 340 – 475 V line-to-line |
| Power input | 0...5 A |
| Frequency | 45 – 65 Hz |
| Current transformer connection | 1 A or 5 A |
| Transformer turns ratios | freely adjustable |
| Connection type | Screw terminals |
| Conductor diameter | up to 4 mm² |
| Threshold output | Optional |
| Auxiliary voltage | 230 V AC optional |
| DIN rail mounting | Optional |
| Hour meter | Integrated |
| Indication | LC-display |
The multifunction display MFA 1001 is an electronic universal measuring instrument for measuring and monitoring electrical quantities in a three-phase AC network, particularly in a four-wire low-voltage network. The device is designed for continuous recording and display of voltage, current, frequency, power, energy, and operating hours. It is intended for built-in applications in control panels and enables clear operator guidance through direct display of all measured values. The display is via an LC screen, which in the MFA 1001 is not equipped with backlighting, ensuring readability in well-lit environments. An integrated operating hour counter records the system's operating time.
Applications
The MFA 1001 is intended for use in industrial and commercial electrical installations where detailed monitoring of electrical parameters is required. It is particularly suitable for installations operating in low-voltage networks and enables real-time recording of measured values. The display is designed for indoor use, with an IP 52 protection rating on the front providing some protection against dust and splashing water. An optional higher protection rating of IP 65 is available, suitable for more demanding environments.
Functions and Equipment in Detail
The device measures voltage between lines (L1-L2, L2-L3, L3-L1) as well as between lines and neutral conductor (L1-N, L2-N, L3-N). Current is recorded for each phase (L1, L2, L3), with the average and maximum current value (since the last reset) being displayed. The display of the averaged maximum current corresponds to the bimetal or drag pointer function used in classical analog measuring instruments. Frequency is measured individually for each phase. Power values include active power (P), reactive power (Q), and power factor (cos φ) per phase, as well as the total for the entire network. Active energy (Wh) is recorded as a reference value. An integrated operating hour counter records operating time in hours.
Technology Explained Simply
The current transformer connections are designed for 1 A or 5 A, with freely adjustable transformer ratios allowing the device to be adapted to different transformer configurations. Connections are made via screw terminals suitable for conductor diameters up to 4 mm². Voltage inputs are rated for 340–475 V (line-to-line) and 196–275 V (line-to-neutral). Frequency measurement is performed in the range of 45–65 Hz. The operating temperature range is between -10 °C and +55 °C.
Compatibility and Accessories
The device is designed for use with current transformers that output either 1 A or 5 A. An optional limit value output is available, which can function as a switching output. When the limit value output is connected, a choice can be made between pulse output and limit value output. An optional auxiliary voltage of 230 V AC is available. DIN rail mounting is also optional and allows for quick installation in control panels.
Mounting and Installation
Mounting is done in a control panel with a cutout of 91 x 91 mm. The front dimensions are 96 x 96 mm. Installation requires connecting the current and voltage inputs according to the terminal assignment. The screw terminals enable secure and quick connections.
Operational Advantages
The MFA 1001 offers comprehensive measuring functions in a compact device. The direct display of all measured values allows for quick assessment of the operating condition. The integrated operating hour counter supports maintenance planning. The ability to freely set transformer ratios increases flexibility when adapting to existing installations. The IP 52 protection rating (optional IP 65) ensures protection against environmental influences.