| General |
| Adapter type | Cable sharing Adapter-Set |
| Manufacturer | Metz Connect |
| Service type | Ethernet/Ethernet |
| Number of adapters in set | 2 |
| Degree of protection | shielded |
| Transmission class | E |
| Standards | IEC 11801, EN 50173-1 |
| Core wiring | 1,2,3,6 |
| Connection type | short, flexible |
| Construction type | narrow, stackable side by side |
| Insert | pairwise, socket and distributor |
| Compatibility | 8-core installation cable |
| Network speed | 10/100 Mbit/s |
The Cable sharing Adapter-Set pnp3 from Metz Connect is a shielded adapter for simultaneous operation of two 4-wire Ethernet services over an 8-wire installation cable. The set consists of two adapters, each installed at different endpoints of the cable: one at the outlet, the other at the distributor. The adapters use the wire assignment 1,2,3,6 to transmit both Ethernet connections over the same cable structure, enabling the use of existing installation cables without additional cabling. The design is slim, allowing the adapters to be inserted side by side into standard 8P8C sockets. The connection is short and flexible, facilitating installation in confined spaces or where space is limited.
Cable sharing enables the use of an existing 8-wire installation cable for two separate 4-wire services, specifically for Ethernet. This is particularly advantageous in existing building installations where additional cabling should be avoided. The technology is based on splitting the cable conductors into two independent 4-wire channels, with conductors 1,2,3,6 used for one service and the remaining conductors (4,5,7,8) for the second service. The adapters are designed for use in networks with 10/100 Mbit/s Ethernet.
Shielded design ensures high immunity against electromagnetic interference and minimizes emission of self-generated interference. This is especially important in environments with high electromagnetic loads, such as offices, server rooms or industrial facilities. The shielding contributes to signal integrity and supports compliance with required transmission characteristics.
Transmission characteristics of Class E according to IEC 11801 and EN 50173-1 ensure the required performance for Gigabit Ethernet applications at the link level. Class E is designed for frequencies up to 100 MHz and enables high-speed data transmission over the entire cable length. Compliance with these standards ensures that the adapters can be used in professional network infrastructures without impairing overall performance.
The adapters are designed for use in
Ethernet networks, specifically for 10/100 Mbit/s connections. They are used in pairs, with one adapter installed at each end of the installation cable. Installation requires no special tools or additional components; the adapters simply plug directly into existing 8P8C sockets. The short, flexible connection facilitates mounting, especially in tight or hard-to-reach areas.
Compatibility is limited to use with 8-wire installation cables that have the required electrical characteristics for Class E transmissions. The adapters are not designed for other services such as ISDN or Token Ring, but specifically for Ethernet/Ethernet configurations. Use in existing networks requires no changes to the cable structure, as the wire assignment 1,2,3,6 is standardized.
The
design is compact and slim, allowing two adapters to be placed side by side in a standard 8P8C socket. This is particularly beneficial in outlets with limited space, where multiple connections are required in parallel. The flexible connection cable allows for flexible positioning and reduces mechanical stress on the sockets.
The
delivery includes a set of 2 pieces, with both adapters being identical and each mounted at one end of the installation cable. Installation is done by simply plugging them into the sockets, without additional mounting work.
Operational advantages include reduced cabling, use of existing infrastructure, and simple installation. The adapters enable network connection expansion without additional cabling, saving time and costs. Compliance with international standards ensures reliable and stable data transmission in professional environments.
The adapters are designed for use in
network infrastructures, particularly in offices, administrative buildings or industrial facilities, where multiple Ethernet connections are to be realized over an existing cable. Use is limited to 10/100 Mbit/s Ethernet, and installation requires no additional tools or configurations.
The
technology is based on splitting the 8 conductors into two independent 4-wire channels, with conductors 1,2,3,6 used for one service and the remaining conductors (4,5,7,8) for the second service. The shielded design and Class E transmission characteristics ensure high signal quality and interference resistance. The short, flexible connection cable facilitates installation and reduces mechanical stress.
Compatibility is limited to 8-wire installation cables that have the required electrical characteristics for Class E transmissions. The adapters are not designed for other services such as ISDN or Token Ring, but specifically for Ethernet/Ethernet configurations. Use in existing networks requires no changes to the cable structure, as the wire assignment 1,2,3,6 is standardized.
Installation is done by simply plugging the adapters into the existing 8P8C sockets at both ends of the installation cable. The slim design allows two adapters to be placed side by side in one socket. The short, flexible connection cable facilitates installation, especially in tight or hard-to-reach areas. No additional tools or configurations are required.
Operational advantages include reduced cabling, use of existing infrastructure, and simple installation. The adapters enable network connection expansion without additional cabling, saving time and costs. Compliance with international standards ensures reliable and stable data transmission in professional environments.