| Additional features |
| Device application | Lighting control |
| Technology type | Electronic |
| Housing variant | Built-in |
| Mounting mode | By screws and claws |
| Number of toggles | 1 |
| Load type | Resistive: 50 - 420 VA; Inductive: 50 - 420 VA |
| [Ue] Rated operational voltage | 220/230 V AC 50/60 Hz |
| Operating ambient temperature | -5…35 °C |
| Degree of protection (IP) | IP20 |
| Height | 71 mm |
| Width | 71 mm |
| Contractual warranty |
| Warranty (in months) | 18 |
| Main features |
| Product series | Merten |
| Product name | Underfloor inserts |
| Compatible product family | PlusLink |
| Product or component type | Multifunction control device |
| Device representation | Mechanism with mounting frame |
| Packaging units |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 5,500 cm |
| VPE 1 width | 7,600 cm |
| VPE 1 length | 7,600 cm |
| Packaging weight (Lbs) | 112,000 g |
| VPE 2 type | CAR |
| VPE 2 quantity | 50 |
| VPE 2 height | 19,400 cm |
| VPE 2 width | 31,100 cm |
| VPE 2 length | 40,400 cm |
| VPE 2 weight | 5,908 kg |
The Merten electronic switch module MEG5151-0000 is a flush-mounted module for lighting control in the PlusLink system. It serves as a multifunction control device for electronic switching of resistive or inductive loads, such as incandescent lamps or NV halogen lighting with conventional transformers. The device is designed for installation in standard flush-mounted boxes and features a mounting mechanism with a frame that can be secured either with claws or screws. The connection terminals are screw terminals, enabling a secure and reliable connection for conductor cross-sections up to 2x2.5 mm².
Applications
This module is suitable for controlling lighting systems in residential and commercial buildings, particularly in installations operated via the PlusLink system. It can be used in single or multiple configurations, with switching capacity potentially reduced depending on installation conditions. When installed in hollow walls or surface-mounted distribution boxes, a load reduction of 25% or 30% is required to ensure adequate heat dissipation. When multiple devices are installed in parallel within one enclosure, the load must be reduced accordingly based on the total number of devices.
Functions and Features in Detail
The device has one output that can be externally controlled via a PlusLink input. Control is performed through the PlusLink network, allowing the module’s function to be flexibly defined across various modules. The switching capacity is 50 to 420 VA for resistive and inductive loads. The device is overload- and short-circuit-proof, ensuring high operational safety. A neutral conductor is not required, as the device operates on a 2-wire system. The rated voltage is 220/230 V AC with a frequency of 50/60 Hz.
Technology Explained Simply
The electronic control is handled by an integrated module that manages the switching function. Control via PlusLink enables decentralized operation, with signals transmitted over a separate network. The screw terminals ensure a stable connection, and the claw-and-screw mounting ensures secure installation in flush-mounted boxes. The protection rating IP20 protects against contact with moving parts and is suitable for indoor use. The operating ambient temperature ranges from -5 °C to 35 °C.
Compatibility and Accessories
The module is part of the PlusLink system and must be combined with a compatible push-button module or sensor module to fully utilize its functionality. Compatible modules include, for example, the Push-button Module Basic, Comfort, Comfort Plus with IR, Wiser Push-button Module, Rotary Dimmer Module, ARGUS Sensor Modules, Timer Modules, and transmitter modules such as Side Station Plus and Central Station Module. Available accessories include PlusLink extensions and distributors (3-phase), which expand the network structure. Suitable frames for the front plate include, for example, the M-SMART frame 1-way in polar white glossy or active white glossy.
Installation and Mounting
Installation is carried out in standard flush-mounted boxes. Mounting is done using claws and screws, with the box required to be aligned according to specifications. Cable connections are made via the screw terminals. During installation, ensure that the total length of PlusLink cables does not exceed 100 m when using a 3-conductor cable cross-section. When multiple devices are installed in one enclosure or in surface-mounted distribution boxes, the load must be reduced accordingly. Installation must be performed by qualified professionals who comply with local regulations and safety standards.
Operational Advantages
The module offers flexible and reliable control of lighting systems. Electronic control enables precise switching, and overload- and short-circuit-proof design enhances safety. External control via PlusLink enables decentralized operation, allowing the system to be flexibly expanded. Operation without a neutral conductor reduces installation costs and simplifies wiring. Compatibility with various modules allows individual adaptation to the specific requirements of each project.