| General |
| Nominal voltage | 450/750 V |
| Test voltage | 2500 V |
| Installation temperature range | +5 °C - +70 °C |
| Temperature range after installation | -30 °C - +70 °C |
| Operation temperature | +70 °C |
| Bending radius | 15 x cable diameter min. |
| Flame retardancy | According to VDE 0472 T. 804 test type B (IEC 332-1) |
| Conductor material | bare copper, fine-stranded |
| Insulation | PVC according to VDE 0207 |
| Sheath colour | light blue RAL 5015 |
| Application | installation in dry rooms, switching and distribution installations, in conduits above and below plaster, as well as in closed installation channels |
The H07V-K 2.5 HBL RAL 5015 is a PVC-insulated single-core cable from manufacturer LTC, designed for use in dry rooms as well as in control and distribution systems. It is suitable for installation in conduits, both above and below plaster, and in closed installation channels. The cable is primarily used for internal wiring of devices, control panels, and distributors, as well as for protected installation in and on lighting fixtures. The maximum rated voltage is 1000 V AC or 750 V DC to earth. Direct installation on trays, gutters, or troughs is not intended.
Applications
This cable is intended for indoor use, particularly in electrical installations where protected routing is ensured. It is commonly used in buildings, industrial facilities, and for wiring electrical devices. Installation takes place in closed channels or conduits to protect the cable from mechanical stress and environmental influences. Use in damp or wet areas is not intended, as the cable is not designed for direct outdoor application.
Functions and Features in Detail
The cable consists of a bare, fine-stranded copper conductor, ensuring high electrical conductivity. Insulation is provided by PVC, specified according to VDE 0207, ensuring high electrical insulation and mechanical stability. The sheath color conforms to VDE 0293 and is finished in light blue (RAL 5015), enabling easy identification within the installation network. The color serves as a visual identifier and supports proper wiring.
Technology Explained Simply
The rated voltage of the cable is 450/750 V, meaning it is designed for electrical systems with a maximum voltage of 450 V between conductors and 750 V between conductor and earth. The test voltage of 2500 V is used for quality assurance and ensures insulation strength. The maximum operating temperature is +70 °C, and the cable may be installed at temperatures between +5 °C and +70 °C. After installation, the cable can be operated at temperatures from -30 °C to +70 °C. The minimum bending radius is 15 times the cable diameter to prevent mechanical damage. Flame retardancy corresponds to test method B according to VDE 0472 Part 804 (equivalent to IEC 332-1), meaning the cable does not propagate flames during a flame test and thus presents limited fire hazard.
Compatibility and Accessories
The cable is compatible with standard electrical installation techniques. It can be connected using common cable lugs, plug connectors, and other connection elements designed for PVC-insulated cables. The light blue color (RAL 5015) corresponds to the marking for protective earth conductor (PE) according to VDE 0293, making it suitable for use as a protective conductor in electrical installations. However, use as a protective conductor requires installation in accordance with applicable standards.
Installation and Mounting
Installation is carried out in closed installation channels, conduits, or in wall mounting below plaster. The cable must not be installed directly on trays, gutters, or troughs. During installation, a minimum temperature of +5 °C must be maintained to avoid damage to the PVC sheath. The bending radius must be at least 15 times the cable diameter to ensure mechanical integrity. Installation is performed in dry rooms, with ambient temperatures after installation ranging from -30 °C to +70 °C.
Operational Advantages
The cable offers high electrical insulation due to PVC insulation and stable mechanical structure due to the fine-stranded copper conductor. The light blue color (RAL 5015) facilitates identification and proper wiring. Flame retardancy according to VDE 0472 Part 804, test method B, ensures limited fire hazard in case of short circuit. The cable is suitable for a wide range of indoor installations and meets safety and reliability requirements in electrical systems.