LTC , EAN: 4013728041107

LTC H07V-K 10,0 Cable 100 m light blue RAL 5015

Cables > Installation systems and industrial management > Wiring cable H05 / 07V-K

LTC H07V-K 10,0 Cable 100 m light blue RAL 5015

Lieske Part No. 968799
Mfg Part No
EAN-Code 4013728041107
Manufacturer LTC
Here only 305,16 EUR
363,14 EUR incl. VAT

Further information for LTC H07V-K 10,0 Cable 100 m light blue RAL 5015

General
Nominal voltage450/750 V
Test voltage2500 V
Installation temperature range+5 °C - +70 °C
Temperature range after installation-30 °C - +70 °C
Operation temperature+70 °C
Bending radius15 x cable diameter
Flame retardancyaccording to VDE 0472 T. 804 test type B
Conductorbare copper, fine-stranded
InsulationPVC according to VDE 0207
Sheath colourlight blue RAL 5015
The H07V-K 10,0 HBL RAL 5015 is a PVC-insulated single-core cable from manufacturer LTC, designed for use in dry rooms as well as in switching and distribution systems. It is suitable for installation in conduits, both above and below plaster, and in closed installation channels. The cable is primarily used for internal wiring of devices, control panels, and distributors, as well as for protected installation in and on lighting fixtures. The maximum rated voltage is 1000 V AC or 750 V DC relative to earth. Direct installation on trays, troughs, or channels is not intended.

Applications
This cable is designed for indoor use, particularly in electrical installations installed in closed or protected conduit systems. It is suitable for wiring electrical devices, distributors, and control panels where stable and reliable power transmission is required. Installation takes place in conduits or channels, protecting the cable from mechanical stress and environmental influences. Applications are in dry rooms, with ambient temperature during installation ranging between +5 °C and +70 °C.

Functions and Features in Detail
The cable consists of a fine-stranded, bare copper conductor, ensuring high electrical conductivity. Insulation is provided by PVC, specified according to VDE 0207, ensuring high electrical insulation performance and mechanical stability. The sheath colour complies with VDE 0293 and is finished in light blue (RAL 5015), enabling easy identification within the installation network. The cable is flame-retardant according to VDE 0472 Part 804, Test Method B, which corresponds to IEC 332-1, ensuring limited flame propagation.

Technical Explanation
The rated voltage of 450/750 V defines the maximum voltage the cable can safely transmit, with 450 V being the voltage between conductors and 750 V being the voltage between conductor and earth. The test voltage of 2500 V serves quality assurance and ensures the insulation remains stable even under increased stress. The maximum operating temperature is +70 °C, meaning the cable can be safely operated under these conditions. During installation, ambient temperature should be between +5 °C and +70 °C; after installation, operation is possible between -30 °C and +70 °C. The minimum bending radius is 15 times the cable diameter to prevent damage to the conductor or insulation due to excessive bending.

Compatibility and Accessories
The cable is designed for use in standard installation systems and can be installed using common installation techniques. It is compatible with standard sockets, switches, and distributors rated for up to 1000 V. The light blue colour (RAL 5015) allows for clear identification within the installation network, especially in systems requiring colour differentiation of cables. The cable is not intended for use in damp or wet environments, as it is not designed for direct outdoor installation.

Installation and Mounting
Installation is carried out in closed systems such as conduits or installation channels. The cable should not be laid directly on trays, troughs, or channels, as this could compromise mechanical stability and electrical safety. Installation takes place in dry rooms, with ambient temperature during installation between +5 °C and +70 °C. The minimum bending radius of 15 times the cable diameter must be observed to ensure cable integrity. After installation, the cable can be operated at temperatures from -30 °C to +70 °C.

Operational Advantages
The cable offers high electrical conductivity due to the fine-stranded copper conductor and reliable insulation via PVC. The flame-retardant design according to VDE 0472 Part 804, Test Method B, enhances operational safety, especially in enclosed spaces. The light blue colour (RAL 5015) facilitates identification and maintenance within the installation network. The cable is designed for long service life and can be safely operated under the specified conditions. Use in closed conduit systems protects the cable from external influences and increases operational safety.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/968799
qrcode für LTC H07V-K 10,0 Cable 100 m light blue RAL 5015