LTC , EAN: 4013728030552

LTC H05V-K 1,0 Cable 1,0 mm² violet

Cables > Installation systems and industrial management > Wiring cable H05 / 07V-K

LTC H05V-K 1,0 Cable 1,0 mm² violet

Lieske Part No. 662307
Mfg Part No
EAN-Code 4013728030552
Manufacturer LTC
Here only 39,38 EUR
46,86 EUR incl. VAT

Further information for LTC H05V-K 1,0 Cable 1,0 mm² violet

General
Nominal voltage300/500 V
Test voltage2000 V
Installation temperature range+5 °C - +70 °C
Temperature range after installation-30 °C - +70 °C
Operation temperature+70 °C
Bending radius15 x cable diameter
Flame retardancyVDE 0472 T. 804 test type B (IEC 332-1)
Conductorbare copper, fine-stranded
InsulationPVC according to VDE 0207
Sheath colourViolet
Cross section1,0 mm²
The H05V-K 1,0 VI is a flexible PVC wiring cable from manufacturer LTC, designed for internal wiring of devices as well as for protected installations in and on luminaires, in conduits, on and under plaster. The cable is specifically designed for use in doorbell and signaling systems. It consists of a bare, fine-stranded copper conductor, insulated with PVC according to VDE 0207. The sheath color complies with the requirements of standard VDE 0293, with the color specified as violet. The cable is rated for a nominal voltage of 300/500 V and features a test voltage of 2000 V, ensuring high electrical insulation performance. The maximum operating temperature is +70 °C, with the cable tolerating temperatures from +5 °C to +70 °C during installation and from -30 °C to +70 °C after installation. The minimum bending radius is 15 times the cable diameter, enabling flexible handling during installation. Flame retardancy corresponds to test method B according to VDE 0472 Part 804 (equivalent to IEC 332-1), ensuring limited flame spread in case of fire.

Applications

The cable is intended for use in protected indoor installations, particularly in the electrical installation of devices, luminaires, and signaling systems. It is suitable for installation in conduits, in pipes, on and under plaster, with installation under plaster only permitted in protected areas. Use is restricted to doorbell and signaling systems, meaning it is not suitable for main power supply or high-current applications.

Functions and Equipment in Detail

The cable features a fine-stranded, bare copper conductor, providing high flexibility and good electrical conductivity. The PVC insulation ensures reliable electrical insulation and mechanical stability. The violet sheath color serves as visual identification and complies with the requirements of standard VDE 0293, which governs color coding for cables in electrical installations. The cable is rated for a nominal voltage of 300/500 V, making it suitable for typical low-voltage applications in signaling and doorbell systems. The test voltage of 2000 V indicates high insulation strength, which is important for safety during installation.

Technology Explained Simply

The designation H05V-K 1,0 VI describes the technical classification of the cable: H stands for halogen-free (not applicable, as PVC is used), 05 for a nominal voltage of 300/500 V, V for PVC insulation, K for a flexible cable, 1,0 for a cross-section of 1.0 mm², and VI for the color violet. Thus, the cable is a flexible, PVC-insulated single-conductor cable with a cross-section of 1.0 mm². The maximum operating temperature of +70 °C means the cable can be safely operated at this temperature without damaging the insulation. The minimum bending radius of 15 times the cable diameter allows flexible installation without damaging the cable. Flame retardancy according to VDE 0472 Part 804, test method B (equivalent to IEC 332-1), means the cable only spreads flame to a limited extent in case of fire, reducing the fire load in the installation.

Compatibility and Accessories

The cable is designed for use in doorbell and signaling systems and can be combined with appropriate connection elements such as connectors, terminals, or switches. Installation takes place in protected areas, such as in conduits or under plaster, with installation under plaster only permitted in protected indoor spaces.

Installation and Mounting

The cable is installed by routing in conduits, pipes, on or under plaster. The cable is flexible and can be easily bent, but the minimum bending radius of 15 times the cable diameter must be observed to avoid damage. Installation takes place in protected indoor areas, with temperatures during installation ranging from +5 °C to +70 °C. After installation, the cable can withstand temperatures from -30 °C to +70 °C. The cable is intended for use in doorbell and signaling systems, and therefore is not suitable for high-current applications. Installation is typically carried out by qualified electricians who comply with the regulations of electrical standards (e.g. VDE 0100).

Operational Advantages

The cable offers high flexibility due to the fine-stranded copper conductor, enabling easy installation. The PVC insulation ensures reliable electrical insulation and mechanical stability. Flame retardancy according to VDE 0472 Part 804, test method B (equivalent to IEC 332-1), reduces the fire load in the installation. The cable is specifically designed for use in doorbell and signaling systems, ensuring safe and reliable performance in these applications. The violet color allows for easy visual identification, simplifying maintenance and fault diagnosis. The maximum operating temperature of +70 °C and the temperature range after installation of -30 °C to +70 °C enable broad applicability in various indoor environments.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111