| General |
| Nominal voltage | 300/500 V |
| Test voltage | 2000 V |
| Installation temperature range | +5 °C - +70 °C |
| Temperature range after installation | -30 °C - +70 °C |
| Operation temperature | +70 °C |
| Bending radius | 15 x cable diameter |
| Flame retardancy | in accordance with VDE 0472 Part 804, test type B |
| Conductor | bare copper, fine-stranded |
| Insulation | PVC according to VDE 0207 |
| Sheath colour | light blue RAL 5015 |
The H05V-K 0.5 HBL RAL 5015 is a flexible PVC wiring cable from manufacturer LTC, designed specifically for internal wiring of devices as well as for protected installations in and on luminaires, in conduits, on and under plaster. The cable is intended exclusively for use in bell and signal systems. It features a bare, fine-stranded copper conductor and PVC insulation complying with VDE 0207 standards. The sheath colour is light blue, corresponding to RAL 5015 as defined by VDE 0293, enabling clear identification within wiring systems.
Applications
This cable is suitable for use in electrical devices where a flexible and strain-resistant connection is required. It is commonly used in the internal assembly of lighting units, in electrical circuits, and in the wiring of signal and bell systems. Installation takes place in protected areas, for example in conduits or under plaster, and the cable is not intended for outdoor use or in damp environments. Its application is limited to low-voltage systems, particularly for signals and auxiliary circuits.
Functions and Features in Detail
The conductor is made of bare, fine-stranded copper, ensuring high flexibility and good electrical conductivity. The PVC insulation provides sufficient electrical insulation resistance and protects the conductor against mechanical stress. The light blue colour (RAL 5015) enables visual differentiation within wiring systems and complies with VDE guidelines for colour coding. The cable is designed for use in bell and signal systems, meaning it is not suitable for main power circuits or higher power demands.
Technical Explanation
The rated voltage is 300/500 V, indicating the maximum voltage at which the cable can be safely operated. The test voltage of 2000 V is used for quality testing and ensures that the insulation does not break down even under increased voltage. The operating temperature is limited to a maximum of +70 °C, and the cable may be installed at temperatures between +5 °C and +70 °C. After installation, the ambient temperature may briefly drop to -30 °C without damaging the cable. The minimum bending radius is 15 times the cable diameter, allowing flexible installation without damaging the insulation or conductor. Flame retardancy according to VDE 0472 T. 804, test method B (equivalent to IEC 332-1), ensures that the cable is only limitedly flammable and does not propagate a live flame in case of fire.
Compatibility and Accessories
The cable is designed for standard installations, particularly in conjunction with electrical devices, luminaires, and signal systems. It is compatible with common terminals, plug connectors, and other connection elements designed for PVC insulation. Installation in conduits or under plaster requires no additional protective measures, as the cable is already designed for protected installations.
Installation and Mounting
Installation should take place at temperatures between +5 °C and +70 °C. The cable must not be excessively bent or stretched; the minimum bending radius is 15 times the cable diameter. Installation in conduits, luminaires, or under plaster is permitted, but the cable is not intended for outdoor use or in damp rooms. Connections should be made using suitable terminals or plug connectors designed for PVC insulation. No special mounting equipment or tools are required, as the cable can be processed using standard methods.
An operational advantage is the high flexibility of the cable, which enables easy installation in confined spaces. Flame retardancy according to VDE 0472 T. 804, test method B, increases operational safety, especially in enclosed spaces. The colour coding in light blue (RAL 5015) facilitates identification and maintenance of the wiring. The cable is designed for use in signal systems, ensuring low current consumption and minimal heat generation.