General
Nominal voltage450/750 V
Test voltage2500 V
Temperature range-25 °C - +80 °C
Operation temperature+80 °C
Bending radius6 x cable diameter
Continuous load15 N/mm²
Flame retardancyVDE 0472 T. 804, test type B
Oil resistanceVDE 0472 T. 803, test type A
Ozone resistanceVDE 0472 T. 805, test type A or A1, test type C
ConductorCopper stranded wire, fine-stranded, class 5
Wire insulationRubber compound according to VDE 0207 T. 20
Conductor markingaccording to VDE 0293-308
Outer sheathRubber compound according to VDE 0207 T. 21
Sheath colourBlack
Protective conductorgn-ge
The H07RN-F 5G16 TR rubber hose cable from LTC is a robust, flexible cable designed for use under extreme mechanical and thermal loads. It is suitable for connecting equipment in agricultural, industrial, and fire-hazardous facilities. Typical applications include large cooking kettles, heating plates, hand lamps, electric tools such as circular saws and drills, household appliances, as well as portable motors or machines on construction sites and in agricultural operations. The cable is also suitable for fixed installation, for example on plaster, in temporary buildings or prefabricated housing, and can be directly laid on components of lifting equipment and machinery.

Applications

The cable is designed for applications involving high mechanical stress, such as frequent bending, tensile load, or movement, as well as thermal stress, such as high ambient temperatures. It is particularly used in environments where high flexibility and durability are required, such as in agriculture, construction, or industrial production environments. Use in fire-hazardous areas is also permitted, with fire behaviour testing according to VDE 0472 T. 804, test type B (equivalent to IEC 332-1), confirming safety under fire conditions.

Functions and Equipment in Detail

The cable consists of fine-stranded copper conductors of class 5, ensuring high flexibility and mobility. Conductor insulation is made from a rubber compound according to VDE 0207 T. 20, providing good electrical insulation and mechanical stability. Conductor identification follows VDE 0293-308, enabling clear identification of individual conductors. The outer sheath is made from an oil-resistant rubber compound according to VDE 0207 T. 21, offering high mechanical strength and resistance to external influences. The sheath colour is black, enhancing visibility and resistance to UV radiation.

Technology Explained Simply

The rated voltage is 450/750 V, making the cable suitable for use in standard AC networks. The test voltage of 2500 V ensures electrical safety under extreme conditions. The maximum operating temperature is +80 °C, with the cable usable during and after installation at temperatures from -25 °C to +80 °C. The minimum bending radius is 6 times the cable diameter, enabling flexible installation. The maximum continuous tensile load is limited to 15 N/mm², considering the total copper cross-section. Oil resistance of the sheath according to VDE 0472 T. 803, test type A, and ozone resistance according to VDE 0472 T. 805, test types A and A1, test type C, ensure long service life even in aggressive environments.

Compatibility and Accessories

The cable is suitable for use with standard connectors, cable lugs, and other connection elements designed for a cross-section of 16 mm². The designation 5G16 indicates that the cable has five conductors, each with a cross-section of 16 mm², with the fifth conductor serving as the protective earth conductor (gn-ge). Use with other cables or accessories must consider the electrical and mechanical requirements of the specific application.

Installation and Mounting

The cable can be installed flexibly, with the minimum bending radius of 6 times the diameter to be observed. During installation, even distribution of tensile load must be ensured to avoid exceeding the maximum continuous tensile load of 15 N/mm². Installation is typically performed without additional protective conduits, as the outer sheath already provides high mechanical and chemical resistance. Connections are made using appropriate cable lugs or connectors designed for a cross-section of 16 mm².

t
Advantages in Operation

The H07RN-F 5G16 TR rubber hose cable offers high mechanical and thermal load capacity, making it suitable for demanding operating conditions. The flexibility of the fine-stranded copper conductors allows for easy handling and installation, even in confined or moving areas. The oil- and ozone-resistant rubber compound of the outer sheath ensures long service life, even in aggressive environments. Compliance with standards VDE 0207 T. 20 and T. 21, as well as testing according to VDE 0472 T. 803, T. 804, and T. 805, guarantees high safety and reliability in operation. The cable is thus a reliable solution for applications requiring high demands on flexibility, durability, and safety.