LTC 500390400000

LTC 500390400000 H07RN-F 1x50 mm² Rubber Sheathed Cable

Cables > Rubber hose / PUR cable > Rubber hose cable H07 RN-F

LTC 500390400000 H07RN-F 1x50 mm² Rubber Sheathed Cable

Lieske Part No. 667272
Mfg Part No 500390400000
EAN-Code
Manufacturer LTC
Here only 17,34 EUR
20,63 EUR incl. VAT

Further information for LTC 500390400000 H07RN-F 1x50 mm² Rubber Sheathed Cable

General
Nominal voltage450/750 V
Test voltage2500 V
Temperature range-25 to +80 °C
Operation temperature+80 °C
Bending radius6 x cable diameter
Continuous load15 N/mm²
Flame retardancyVDE 0472 T. 804, test type B
Oil resistanceVDE 0472 T. 803, test type A
Ozone resistanceVDE 0472 T. 805, test type A or A1, test type C
ConductorCopper stranded wire, fine-stranded, class 5
Wire insulationRubber compound according to VDE 0207 T. 20
Conductor markingaccording to VDE 0293-308
Outer sheathRubber compound according to VDE 0207 T. 21
Sheath colourBlack
The rubber hose cable H07RN-F 1X50 QMM 500M from LTC is a heavy-duty, flexible cable designed for use under extreme mechanical and thermal loads. It is suitable for connecting equipment in agricultural, commercial, and fire-hazardous facilities. Typical applications include large cooking kettles, heating plates, hand lamps, electric tools such as circular saws or drills, household appliances, as well as portable motors and machines on construction sites. The cable is also suitable for fixed installation, for example on plaster, in temporary buildings or prefabricated housing, and can be laid directly on components of lifting equipment or machines.

Applications

The cable is designed for applications where high mechanical stress, such as frequent bending, tensile load, or contact with sharp edges, as well as thermal stress from high ambient temperatures or direct heat generation from connected devices, occurs. It is used in environments where high flexibility and durability of the connection are required, for example in agriculture, construction, or industry. Installation often takes place in moving or mobile systems, where a permanent yet flexible connection is necessary.

Functions and Equipment in Detail

The cable consists of a fine-stranded copper conductor of class 5, designed for high flexibility and load capacity. The core insulation is made of a rubber compound according to VDE 0207 T. 20, ensuring good electrical insulation and mechanical stability. Core identification follows VDE 0293-308, enabling clear identification of the conductors. The outer sheath is made of a rubber compound according to VDE 0207 T. 21 and is black, providing good visibility and resistance to external influences.

Technology Explained Simply

The rated voltage is 450/750 V, indicating the maximum voltage at which the cable can be safely operated. The test voltage of 2500 V serves as a safety test to verify insulation strength. The cable can be installed and operated at temperatures from -25 °C to +80 °C, with a maximum operating temperature of 80 °C. The minimum bending radius is six times the cable diameter, allowing flexible installation without damage. The continuous tensile load is limited to a maximum of 15 N/mm², considering the total copper cross-section. The flammability behaviour corresponds to test method B according to VDE 0472 T. 804 (equivalent to IEC 332-1), indicating limited flammability under direct flame exposure. The sheath is oil-resistant according to VDE 0472 T. 803, test method A, and ozone-resistant according to VDE 0472 T. 805, test methods A and A1, test method C, ensuring high resistance to environmental influences such as oil or ozone.

Compatibility and Accessories

The cable is designed for use with electrical devices and machines that require high mechanical and thermal load capacity of the connection. It is compatible with standard plugs and socket outlets designed for a rated voltage of 450/750 V. Use with other cables or accessories must consider the electrical and mechanical requirements of the specific application.

Installation and Mounting

Installation is carried out by direct laying on components, plaster surfaces, or in temporary structures. The cable can also be laid on movable machines or lifting equipment. During installation, a minimum bending radius of six times the cable diameter must be observed to avoid damaging the conductor. Installation takes place in environments where the temperature ranges between -25 °C and +80 °C. The tensile load during installation and operation must not exceed 15 N/mm².

Advantages in Operation

The cable offers high mechanical strength and flexibility, making it particularly suitable for moving or mobile applications. Resistance to oil, ozone, and high temperatures ensures a long service life even in demanding environments. Clear core identification according to VDE 0293-308 simplifies installation and maintenance. The black-coloured rubber compound of the outer sheath provides good visibility and protection against external influences.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/667272
qrcode für LTC 500390400000 H07RN-F 1x50 mm² Rubber Sheathed Cable