| General |
| Fuse type | slow-acting |
| Class | J |
| Dimension | 27x60 mm |
| Operating voltage | 600 V AC |
| Degree of protection | IEC Type-2-No-Damage |
| Indication | visual open SmartSpot |
| Property | Time delay |
| Current limiting | excellent |
| Application range | Main, branch and distribution circuits |
The Lindner AJT60 is an NH fuse of type Amp-Trap 2000, designed as a slow-acting fuse of Class J. It is used in the dimension 27x60 mm and is designed for alternating voltages up to 600 V AC. The fuse serves as a protective function in electrical installations, particularly in main, branch, and distribution circuits, where IEC Type-2 No-Damage protection is required. This protection type ensures that in the event of a short circuit, the fuse limits the current quickly enough to prevent damage to the electrical installation and connected devices. The fuse is suitable for all types of loads, including those with high inrush currents such as motors and transformers.
Fuse type and protective function
The AJT60 is a slow-acting fuse, meaning it tolerates short-term current surges, such as those occurring during the startup of motors or transformers, without tripping. This time-delay characteristic enables reliable protection without unnecessary shutdowns. At the same time, the fuse offers excellent current-limiting capability, reducing the current to a safe level during a short circuit. This protects the electrical installation and connected devices from thermal and mechanical stress.
Visual indication and mounting
The fuse features a visual open SmartSpot fuse indicator, which allows the status of the fuse to be easily identified. This indicator enables quick inspection to determine whether the fuse is intact or has tripped. The fuse requires very little mounting space, making it particularly suitable for installations with limited space. Its compact design facilitates installation and maintenance in enclosures and distributors.
Technology and materials
The AJT60 is based on advanced material technology that enhances the performance and reliability of the fuse. The materials are selected to withstand the high thermal and electrical stresses that occur during a short circuit. The fuse is designed for use in electrical installations manufactured according to IEC standards and meets the requirements for Type-2 protection, ensuring high safety for the entire installation.
Applications
The fuse is intended for use in main, branch, and distribution circuits. It is particularly suitable for installations where motors, transformers, or other devices with high inrush currents are operated. The fuse can be used in industrial installations, buildings, or other electrical systems where reliable and fast short-circuit protection is required. The use in combination with suitable fuse holders is necessary to integrate the fuse into the installation.
Compatibility and accessories
The AJT60 is designed for use in NH fuse holders suitable for the dimension 27x60 mm. The fuse is part of the Amp-Trap 2000 series and can be combined with other products from this series to ensure a consistent protection strategy in the installation. The use of fuse holders that meet the required electrical and mechanical specifications is necessary to ensure the function of the fuse.
Operational advantages
The fuse offers high reliability and fast protection during short circuits. The visual indicator simplifies maintenance and inspection, as the status of the fuse can be quickly checked. The small mounting area saves space in enclosures and distributors. The time-delay characteristics ensure that the fuse does not trip during short-term current surges, increasing operational safety. The fuse is designed for use in installations manufactured according to IEC standards and meets the requirements for Type-2 protection, ensuring high safety for the entire installation.