Further information for Lapp 0046040/50 ÖLFLEX HEAT 180 SiHF 16G1,5 cable 50 m
General
Operating voltage
300/500 V
Temperature range
-60 to +180 °C
Wire identification
numbers
Material
Silicone mixture
Flexibility
Flexible
Chemical resistance
Resistant to many oils, plant and animal fats
Flame retardancy
in accordance with EU Directive 305/2011 (BauPVO/CPR)
Gases in case of fire
low corrosivity
Application environment
dry and damp rooms
Application
wiring of machine-internal and cross-system control circuits
Approvals
DIN EN IEC 60754-1, DIN EN IEC 60754-2
Cable construction
Flexible
Safety features
halogen-free, low corrosivity of gases in case of fire
Operating conditions
Fixed installation, occasional movement without tensile stress
Wiring
control circuits in machines and plants
Maintenance
simple wiring, flexible structure
Core concepts
heat-resistant cable, silicone cable, halogen-free, operating voltage 300/500 V, temperature range -60°C to +180°C, flexible
Halogen free
Insulating properties after flaming
The ÖLFLEX® HEAT 180 SiHF 16G1,5 cable from Lapp is a heat-resistant silicone cable designed for use in industrial applications with high thermal loads. It features an operating temperature range of -60 °C to +180 °C, making it suitable for environments where high temperatures occur, such as in machine and plant engineering. The cable is flexible and intended for fixed installation as well as occasional movement without tensile stress. It is universally suitable for wiring internal machine and plant control circuits, particularly in dry and damp rooms.
Applications
The cable is resistant to many oils, plant and animal fats, and exhibits a wide range of chemical resistance. It is therefore particularly suitable for applications in the food industry, chemical industry, or automotive manufacturing, where high temperatures and aggressive environmental conditions prevail. The flexible construction allows use in limited space, making it especially advantageous for compact machine design concepts.
Functions and Features in Detail
The cable consists of a halogen-free conductor insulation and outer sheath compound, classified according to DIN EN IEC 60754-1. This ensures low generation of toxic gases in case of fire. The insulation and outer sheath are made of a silicone compound that retains insulating properties even after flaming in a stationary state. Conductor identification is done by numbers, enabling easy assignment and wiring.
Technical Explanation
The silicone insulation allows an operating temperature up to +180 °C, although sufficient ventilation is required, as silicone cables may prematurely lose their mechanical properties above +100 °C in the absence of oxygen. The cable is rated for an operating voltage of 300/500 V, providing sufficient electrical insulation for many industrial applications. The flexible structure ensures easy handling and installation, especially in tight construction gaps.
Compatibility and Accessories
The cable is universally applicable and can be integrated into various industrial systems. It is designed for use in control circuits and is suitable for connecting sensors, actuators, and control devices. Compatibility with standard terminals and connectors is ensured, as the cable meets standard electrical and mechanical requirements.
Installation and Mounting
The cable is intended for fixed installation and can be moved occasionally, provided no tensile stress occurs. The flexible structure facilitates installation, especially in narrow or complex geometries. Sufficient ventilation is required at high temperatures to ensure the cable's service life.
Operational Advantages
The high heat resistance up to +180 °C, chemical resistance, and halogen-free composition of the insulation make the cable a reliable solution for demanding industrial environments. The low corrosivity of gases in case of fire (according to DIN EN IEC 60754-2) increases safety during use. The flexible construction and easy wiring via numbered conductors support efficient installation and maintenance.
The cable is classified according to EU Directive 305/2011 (BauPVO/CPR), with exact article number selection available on the LAPP website. Information on fire behaviour classification is part of the product documentation and complies with applicable standards.
Protection Rating
Use in dry and damp rooms is explicitly stated, indicating a certain degree of moisture resistance, although no specific protection class is implied.
Operating Voltage
The cable is rated for an operating voltage of 300/500 V, which is sufficient for many industrial control and signal applications. The insulation ensures safe electrical separation of the conductors.
Conductor Identification
The conductors are marked with numbers, enabling clear assignment and wiring. This method is common in industrial electrical engineering and facilitates installation and maintenance.
Material
The insulation and outer sheath are made of a silicone compound designed for high heat resistance and chemical resistance. The halogen-free composition reduces fire hazard and the formation of toxic gases.
Temperature Range
The cable can withstand temperatures from -60 °C to +180 °C. The upper limit requires sufficient ventilation to maintain mechanical properties.
Flexibility
The cable is flexible and suitable for fixed installation as well as occasional movement without tensile stress. The flexible structure facilitates installation in confined spaces.
Application Environment
The cable is suitable for dry and damp rooms and can be used in various industrial environments, particularly in machine and plant engineering.
Fire Behaviour
The cable is classified according to EU Directive 305/2011 (BauPVO/CPR). The exact classification is available on the LAPP website. The halogen-free composition ensures low corrosivity of gases in case of fire (according to DIN EN IEC 60754-2).
Chemical Resistance
The cable is resistant to many oils, plant and animal fats, and exhibits a wide range of chemical resistance, making it suitable for demanding industrial environments.
Purpose of Use
The cable is universally suitable for wiring internal machine and plant control circuits. It is particularly suitable for applications where high temperatures and chemical stresses occur.
Approvals and Standards
The cable complies with DIN EN IEC 60754-1 and DIN EN IEC 60754-2 regarding halogen-free composition and low corrosivity of gases in case of fire. Classification according to EU Directive 305/2011 (BauPVO/CPR) is also provided.
Cable Construction
The flexible construction of the cable enables easy installation, especially in limited space. The silicone insulation ensures high heat resistance and chemical resistance.
Safety Properties
The halogen-free composition of the insulation and sheath reduces fire hazard and the formation of toxic gases. The insulating properties after flaming in a stationary state increase safety during use.
Operating Conditions
The cable is intended for fixed installation and occasional movement without tensile stress. Sufficient ventilation is required at temperatures above +100 °C to ensure service life.
Reliability
The high heat resistance, chemical resistance, and halogen-free composition ensure high reliability in demanding industrial applications. The flexible structure and easy wiring support efficient installation and maintenance.
Application Areas
The cable is suitable for use in the food industry, chemical industry, automotive manufacturing, and machine building, where high temperatures and aggressive environmental conditions prevail.
Wiring
The cable is suitable for wiring control circuits in machines and plants. Numbering of the conductors facilitates assignment and wiring.
Maintenance
The flexible structure and easy wiring facilitate maintenance and repair. The high heat resistance and chemical resistance increase the cable's service life.