Lapp 0011190, EAN: 4044773006100

Lapp 0011190 ÖLFLEX 191CY 7G1,5 control cable shielded

Cables > Control line > Flexible Control lines

Lapp 0011190 ÖLFLEX 191CY 7G1,5 control cable shielded

Lieske Part No. 445212
Mfg Part No 0011190
EAN-Code 4044773006100
Manufacturer Lapp
Here only 7,94 EUR
9,45 EUR incl. VAT

Further information for Lapp 0011190 ÖLFLEX 191CY 7G1,5 control cable shielded

General
Degree of protectionfor dry, damp and oil-containing environments -
Operating voltage300/500 V
Test voltage4000 V
Conductor cross section7G1,5 -
Wire identificationnumbers -
ScreeningCopper shielding braid with high coverage -
Oil resistanceenhanced according to DIN EN 50363-4-1 (TM5) -
Inner sheathExtruded -
CertificationUL, CSA, EAC -
ApplicationFor medium mechanical stress, fixed installation, occasional movement without tensile stress -
Outer sheath materialPVC -
Chemical resistanceresistant to acids and alkalis -
Flexibilityfor occasional movement without tensile stress -
Space-savingby reduced wall thicknesses -
Multiple certificationUL, CSA, EAC -
Lifespanincreased due to robust construction -
Safetyhigh electrical safety due to 4000V test voltage -
Utilizationin machine-internal and cross-system control circuits -
ApprovalUL recognized, CSA, EAC -
Constructionshielded, PVC outer sheath, extruded inner sheath -
Resistanceresistant to acids, alkalis, oil -
CertificationsUL, CSA, EAC -
Requirementsfor medium mechanical stress -
InstallationFixed installation, occasional movement without tensile stress -
Cable typecontrol cable -
ManufacturerLapp -
The control cable ÖLFLEX® 191 CY 7G1,5 from Lapp is a flexible multi-standard cable designed for wiring in industrial applications. It is suitable for medium mechanical stress and is used for fixed installation as well as for occasional movement without tensile stress. The cable is particularly suitable for environments where oil, moisture or dryness prevail, and offers high chemical resistance against acids and alkalis. The PVC outer sheath provides a robust protective layer that remains stable even in oil-containing environments. The cable is universally applicable in machine-internal and plant-wide control circuits.

Applications
The ÖLFLEX® 191 CY 7G1,5 is intended for industrial plants, machine construction and automation technology. It is used in environments with medium mechanical load where a flexible but stable connection is required. The cable is particularly suitable for applications in manufacturing technology, the packaging industry and robotics, where it is installed in oil-containing or moist areas. The high chemical resistance of the PVC sheath enables use in environments with aggressive media.

Functions and Equipment in Detail
The cable features a shielded construction with a copper braided shield that has a high coverage rate. This provides effective protection against electromagnetic interference, which can occur when used in industrial environments with electrical devices and motors. Conductor identification is done by numbers, enabling simple and secure wiring. The cable is available in conductor cross-sections up to 120 mm², making it flexible for various requirements.

Technology Explained Simply
The ÖLFLEX® 191 CY 7G1,5 is equipped with an extruded inner sheath that provides additional robustness and extends the cable’s service life. The reduced wall thicknesses ensure space-saving installation, especially in tight installation situations. The test voltage is 4000 V, ensuring high electrical safety. The cable is oil-resistant according to DIN EN 50363-4-1 (TM5), meaning it remains stable even in environments with increased oil load. The operating voltage is U0/U: 300/500 V, which is sufficient for many industrial applications.

Compatibility and Accessories
The cable is equipped with multiple certifications, including UL and CSA certification, enabling use in the North American market. The multi-standard approval reduces part variety and simplifies logistics. The cable is suitable for use in various standard environments, including EAC, increasing its international usability.

Installation and Mounting
The cable is designed for fixed installation and can be used for occasional movement without tensile stress. The flexible construction facilitates installation in tight spaces and complex routing. Conductor identification by numbers supports error-free installation. The cable requires no special tools or additional components for mounting.

Operational Advantages
The ÖLFLEX® 191 CY 7G1,5 offers high reliability in industrial environments. The combination of oil-resistant sheath, electromagnetic shielding and high electrical safety ensures long service life and low maintenance. The multi-certification enables universal use and reduces the number of required cable types. The space-saving construction with reduced wall thicknesses facilitates installation in confined spaces.

Protection Rating
The cable is designed for use in dry, moist and oil-containing environments. The PVC outer sheath offers resistance to acids and alkalis. The cable is not specifically designed for outdoor use, but for industrial indoor applications.

Certifications
The cable is UL- and CSA-tested, enabling use in the North American market. The multi-certification also includes EAC, increasing its international usability. The approvals are valid according to the technical data provided by the manufacturer.

Conductor Cross-Section
The cable has a conductor cross-section of 7G1,5, making it suitable for a wide range of control applications. Availability in conductor cross-sections up to 120 mm² offers flexibility for different requirements.

Shielding
Shielding is provided by a copper braid with high coverage, effectively reducing electromagnetic interference. This is particularly important in environments with strong electromagnetic fields, such as those found in industry.

Test Voltage
The test voltage is 4000 V, ensuring high electrical safety. This is an important factor for the reliability and safety of the cable in operation.

Oil Resistance
The cable is highly oil-resistant according to DIN EN 50363-4-1 (TM5), meaning it remains stable even in environments with increased oil load. This is particularly important in applications where oil or other liquid media are present.

Inner Sheath
The extruded inner sheath provides additional robustness and extends the cable’s service life. It protects the conductors from mechanical stress and increases the overall safety of the cable.

Operating Voltage
The operating voltage is U0/U: 300/500 V, which is sufficient for many industrial applications. The cable is designed for use in control circuits requiring these voltage values.

Conductor Identification
Conductor identification is done by numbers, enabling simple and secure wiring. This reduces the risk of incorrect connections during installation.

Multi-Certification
The cable features multi-certifications, including UL, CSA and EAC, enabling universal usability and reducing part variety. This is particularly beneficial for companies operating in different markets.

Space-Saving
The reduced wall thicknesses ensure space-saving installation, especially in tight installation situations. This facilitates routing in complex machine construction systems.

Chemical Resistance
The PVC outer sheath is resistant to acids and alkalis, making the cable suitable for chemically demanding environments. This increases the service life and reliability of the cable.

Flexibility
The cable is flexible and can be used for occasional movement without tensile stress. This makes it particularly suitable for applications where some movement is required without mechanically overloading the cable.

Universal Use
The cable is universally applicable for wiring of machine-internal and plant-wide control circuits. The combination of flexibility, chemical resistance and electromagnetic shielding makes it a versatile solution for industrial applications.

Reduced Part Variety
The multi-certification enables use of the cable in various standard environments, reducing the number of required cable types. This leads to savings in logistics and simplifies ordering processes.

International Usability
The UL and CSA certification enables use of the cable in the North American market. The EAC approval extends usability to other markets.

Longevity
The combination of oil-resistant sheath, robust inner sheath and high electrical safety ensures a long service life for the cable. This reduces maintenance costs and increases operational safety.

Safety
The high test voltage of 4000 V and electromagnetic shielding ensure high electrical safety. This is particularly important in industrial environments where safety requirements are high.

Easy Installation
The flexible construction and conductor identification by numbers facilitate installation. The cable requires no special tools or additional components for mounting.

Multi-Certification
The cable is UL- and CSA-tested, enabling use in the North American market. The multi-certification also includes EAC, increasing its international usability. The approvals are valid according to the technical data provided by the manufacturer.

Conductor Cross-Section
The cable has a conductor cross-section of 7G1,5, making it suitable for a wide range of control applications. Availability in conductor cross-sections up to 120 mm² offers flexibility for different requirements.

Shielding
Shielding is provided by a copper braid with high coverage, effectively reducing electromagnetic interference. This is particularly important in environments with strong electromagnetic fields, such as those found in industry.

Test Voltage
The test voltage is 4000 V, ensuring high electrical safety. This is an important factor for the reliability and safety of the cable in operation.

Oil Resistance
The cable is highly oil-resistant according to DIN EN 50363-4-1 (TM5), meaning it remains stable even in environments with increased oil load. This is particularly important in applications where oil or other liquid media are present.

Inner Sheath
The extruded inner sheath provides additional robustness and extends the cable’s service life. It protects the conductors from mechanical stress and increases the overall safety of the cable.

Operating Voltage
The operating voltage is U0/U: 300/500 V, which is sufficient for many industrial applications. The cable is designed for use in control circuits requiring these voltage values.

Conductor Identification
Conductor identification is done by numbers, enabling simple and secure wiring. This reduces the risk of incorrect connections during installation.

Multi-Certification
The cable features multi-certifications, including UL, CSA and EAC, enabling universal usability and reducing part variety. This is particularly beneficial for companies operating in different markets.

Space-Saving
The reduced wall thicknesses ensure space-saving installation, especially in tight installation situations. This facilitates routing in complex machine construction systems.

Chemical Resistance
The PVC outer sheath is resistant to acids and alkalis, making the cable suitable for chemically demanding environments. This increases the service life and reliability of the cable.

Flexibility
The cable is flexible and can be used for occasional movement without tensile stress. This makes it particularly suitable for applications where some movement is required without mechanically overloading the cable.

Universal Use
The cable is universally applicable for wiring of machine-internal and plant-wide control circuits. The combination of flexibility, chemical resistance and electromagnetic shielding makes it a versatile solution for industrial applications.

Reduced Part Variety
The multi-certification enables use of the cable in various standard environments, reducing the number of required cable types. This leads to savings in logistics and simplifies ordering processes.

International Usability
The UL and CSA certification enables use of the cable in the North American market. The EAC approval extends usability to other markets.

Longevity
The combination of oil-resistant sheath, robust inner sheath and high electrical safety ensures a long service life for the cable. This reduces maintenance costs and increases operational safety.

Safety
The high test voltage of 4000 V and electromagnetic shielding ensure high electrical safety. This is particularly important in industrial environments where safety requirements are high.

Easy Installation
The flexible construction and conductor identification by numbers facilitate installation. The cable requires no special tools or additional components for mounting.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/445212
qrcode für Lapp 0011190 ÖLFLEX 191CY 7G1,5 control cable shielded