| General |
| Material | Cu-ETP blank |
| Cable cross-section | 70 - 95 mm² |
| Screw size | M12 |
| Number of screws | 4 |
| Screw material | Bronze |
| Screw strength class | F 60 |
| Norm | VDE 0295 Class 1 and 2 |
| Application range | Lightning protection zone, outdoor use |
| Screw standard | DIN 84 / DIN 933 |
The cable lug 588R12BK from Klauke is a stamped, bare terminal cable lug, specifically developed for the screw connection area of conductors according to VDE 0295 Class 1 and 2. It is particularly suitable for use in lightning protection systems as well as for outdoor installations. The material Cu-ETP (copper, electrolytically refined) ensures high electrical conductivity and mechanical strength. The construction with four screws enables a secure and stable connection for cables with a cross-section of 70 to 95 mm². The screws are made of bronze and comply with standards DIN 84 (for hex socket screws) and DIN 933 (for hex head screws), with a strength class F 60 specified. The screw size is M12, providing sufficient fastening force for the intended application.
Cable lug
The cable lug is designed as a stamped component, enabling precise fit and even distribution of mechanical load on the cable. The bare, uninsulated contacts ensure low transition resistance and a reliable electrical connection. The use of Cu-ETP as material is typical for applications requiring high electrical conductivity and corrosion resistance. The bare contacts require careful handling, especially in outdoor installations, to prevent oxidation or contamination.
Application areas
The cable lug is primarily intended for use in lightning protection systems, where a reliable and durable electrical connection is crucial. Outdoor use is also possible, although the bare contacts require special care due to the lack of insulation. Use in industrial electrical installations, grounding systems, or other areas involving high current loads and mechanical stress is also suitable. The standard VDE 0295 Class 1 and 2 defines the mechanical and electrical requirements for the conductors used, with Class 1 referring to soft-drawn copper and Class 2 to soft-drawn copper with increased strength.
Functions and equipment in detail
The cable lug features four screws that apply even pressure on the cable, ensuring a secure connection. The screws are made of bronze, offering high corrosion resistance and mechanical strength. The strength class F 60 corresponds to a minimum tensile strength of 600 MPa, suitable for demanding environments. The M12 screw size provides sufficient fastening force to securely hold the cables. Installation is done by screwing, with the screws equipped with an internal hex (DIN 84) and a hex head (DIN 933).
Technology explained simply
The use of Cu-ETP as material ensures high electrical conductivity, which is important for minimal energy losses and stable current transmission. The bare contacts require careful handling, especially in outdoor installations, to avoid oxidation or contamination. The four screws ensure even distribution of pressure on the cable, guaranteeing a secure and durable connection. The strength class F 60 of the screws means they have a minimum tensile strength of 600 MPa, suitable for use in demanding environments.
Compatibility and accessories
The cable lug is designed for cables with a cross-section of 70 to 95 mm² and is suitable for conductors according to VDE 0295 Class 1 and 2. Use in lightning protection systems and outdoor applications is intended, although the bare contacts require special care.
Mounting and installation
Installation is done by screwing the cables into the cable lug. The four screws must be tightened evenly to ensure uniform pressure on the cable. The use of an appropriate screwdriver or electric screwdriver is recommended to ensure even torque distribution. The bare contacts require careful handling, especially in outdoor installations, to prevent oxidation or contamination.
Advantages in operation
The cable lug provides a secure and stable connection for cables with a cross-section of 70 to 95 mm². The use of Cu-ETP as material ensures high electrical conductivity and mechanical strength. The four screws ensure even distribution of pressure on the cable, guaranteeing a secure and durable connection. The strength class F 60 of the screws means they have a minimum tensile strength of 600 MPa, suitable for use in demanding environments. Outdoor use is possible, although the bare contacts require special care.