| General |
| Product type | Connection sleeve |
| Function | Fire protection enclosure |
| Degree of protection | Airtight |
| Material | halogen-free |
| Application range | Fire protection walls |
| Fire resistance class | EI30 to EI90 |
The connection sleeve 9060-68 from Kaiser is a component specifically designed for fire protection walls to enable safe passage of electrical installations. It is used in walls with fire resistance ratings EI30 to EI90 to maintain the fire resistance duration even when cables are installed. The sleeve ensures a smoke-tight room seal, thus protecting life safety and property. The function is based on an integrated fire-sealing layer former, which quickly and reliably seals the installation opening in the event of fire. This prevents the spread of flames and smoke gases.
Applications
The connection sleeve 9060-68 is intended for use in fire protection walls with fire resistance durations of EI30 to EI90. It enables the passage of electrical cables through the wall structure without compromising the fire protection function. The application is particularly relevant in buildings with high fire safety requirements, such as public facilities, hospitals, or office buildings with increased safety needs. The airtight design ensures effective sealing against smoke and heat.
Functions and Features in Detail
The sleeve features an integrated fire-sealing layer former, which is activated in the event of fire. This forms a dense layer that seals the opening in the wall material, preventing the penetration of flames and smoke gases. The construction is designed to retain its function even at high temperatures. The use of halogen-free materials reduces the formation of toxic gases in the event of fire, increasing safety within the building. The airtight design ensures that no smoke gases can escape through the opening.
Technical Explanation
The fire-sealing layer former in the connection sleeve 9060-68 reacts to heat development during a fire. Depending on the material composition, it shrinks or expands to form a dense, heat-insulating layer that seals the opening in the wall material. This reaction occurs within a short time, ensuring that the fire resistance of the wall is not compromised. The materials are selected to avoid releasing toxic gases under fire conditions, enhancing building safety. The airtight construction prevents smoke and heat from entering adjacent rooms through the opening.
Compatibility and Accessories
The connection sleeve 9060-68 is designed for use in fire protection walls with fire resistance ratings EI30 to EI90. It is specifically designed for electrical installations and can be used in combination with other fire protection boxes and systems from Kaiser. The use of halogen-free materials allows for safe integration into existing fire protection concepts.
Installation and Mounting
Installation is carried out in the designated opening of the fire protection wall. The sleeve is installed to safely pass the electrical installation while maintaining the fire resistance of the wall. The airtight design requires careful installation to ensure no gaps are created that could impair functionality.
a
connection sleeve, functioning as a
fire protection box, with
airtight construction and
halogen-free materials, specifically for
fire protection walls with fire resistance ratings
EI30 to EI90.
Operational Advantages
The use of the connection sleeve 9060-68 ensures continuous fire resistance of the wall, even when electrical cables are passed through. The smoke-tight sealing increases safety within the building, especially during a fire, as it prevents the spread of smoke and heat. The use of halogen-free materials reduces the risk of toxic gases, facilitating the rescue of people. The construction is robust and suitable for use in critical areas where high fire safety requirements exist.