Further information for Kaiser 1564-01 Fire Protection Connection Box UP EI30-EI120
General
Fire protection class
EI30-EI120
Halogen free
The Kaiser fire protection box for recessed installation type 1564-01 is a connection box specifically developed for use in fire protection walls in solid construction. It ensures the maintenance of the fire resistance duration of walls with fire protection class EI30 to EI120, even when electrical installations are built into the wall. The box is intended for installation in recessed and hollow wall constructions and serves as a smoke-tight seal in the event of fire, particularly when the minimum remaining wall thickness of 60 mm is exceeded, whether in single-sided or opposite-side installation.
Applications
The box is used in buildings where fire protection requirements apply to walls, for example in office buildings, apartments or industrial facilities. It is suitable for the installation of electrical devices such as switches, socket outlets or other consumers that must be mounted in fire protection walls. The application is particularly in walls that must have a fire resistance duration of 30 to 120 minutes to ensure safety in the event of fire.
Functions and equipment in detail
An integrated thermal insulation layer former ensures rapid and reliable sealing of the installation opening in the event of fire. This prevents the spread of flames and smoke gases. The box also prevents fire propagation that could occur due to insufficient remaining wall thickness. The construction is designed to maintain the required fire protection even when the wall thickness is reduced below 60 mm. The box is halogen-free, meaning that no toxic halogen compounds are released during a fire.
Technology explained simply
The fire protection box 1564-01 operates with a special insulation layer former that is activated in the event of fire. This former shrinks or expands and completely fills the opening in the wall. This creates a tight seal that prevents the penetration of heat, smoke and flames. The box is designed for a depth of 60 mm, which corresponds to the standard depth for recessed installations in many building constructions. The halogen-free design reduces the formation of toxic gases in the event of fire, increasing safety in the building.
Compatibility and accessories
For use with the box 1564-01, the accessory 1184-94 cover HWD30-90 is available, which has a fire protection class F30 to F90. This cover can be used to seal the box and supports the smoke-tight sealing. The combination of box and cover enables a complete fire protection solution for electrical installations in walls with increased safety requirements.
Installation and mounting
The box is installed in the wall, with the installation opening prepared according to the specified depth of 60 mm. Mounting takes place in the recessed area, where the box is inserted into the wall and then plastered over. Installation is carried out before the plastering phase to ensure that the box is correctly positioned and securely anchored. The use of the box requires no special tools or additional materials, except for the necessary plaster for finishing.
Advantages in operation
The box 1564-01 offers a reliable fire protection solution for electrical installations in solid walls. It enables compliance with fire protection requirements even under non-ideal wall conditions, such as reduced remaining wall thickness. The halogen-free design improves safety in the event of fire, as no toxic gases are released. The integration of the insulation layer former ensures automatic and effective sealing without requiring additional measures. The box is therefore a practical solution for electricians who must meet fire protection requirements.