Further information for Jung FMAS16REG - radio actuator REG 1 channel
REG housing 2 TE
new system function: fully encrypted radio transmission (AES-CCM) from eNet Server software version 2.0
Intended use
Switching of lighting
Operation with suitable eNet radio transmitters
Operation with power supply 12 V REG (item no. NT 1220 REG VDC) and eNet radio receiver module REG (item no. FM FK 32 REG) or eNet server
Installation on top hat rail according to DIN EN 60715 in sub-distribution board
Product features
Operating mode switch for switching/touch actuator switching or parameterization via eNet server
Status feedback to radio transmitter
Scene operation possible
Output can be switched with Prog button
Status display with LED
Switching mode:
Switch-on telegram: Device switches on
Switch-off telegram: Device switches off
Touch mode:
The relay contact remains closed as long as switch-on or switch-off telegrams are received
The maximum switch-on time is 60 seconds
With eNet server adjustable:
Flashing function
Run-on time Switch
-on/off delay
Normally open or normally closed operation
Switch-off warning
Minimum switching repetition time
Operating locks
Permanently on, permanently off
Additional functions with eNet server:
Fully encrypted radio transmission (AES-CCM) from eNet server software version 2.0
Update of the device software
Read error memory
Nominal voltage: AC 230 V ~, 50/60 Hz
Ambient temperature: ?5 ... +45 °C
Switching current at AC 230 V ~
Ohmic: 16 A
For switching current
10 A Connection cable 2.5 mm2
Fluorescent lamps: 4 AX
Contact type: µ
Standby power: max. 0.2 W
Connected load Incandescent
lamps: 2300 W
HV halogen lamps: 2000 W
Electronic transformers: 1500 W
HV LED lamps: typically 500 W
Compact fluorescent lamps: typically 500 W
Inductive Transformers: 1000 VA
Fluorescent lamps uncompensated: 920 VA
Capacitive load: 690 VA (560 µF)
Connection Outputs
Connection type: Screw terminals
single-wire: 1 x 1.5 ... 4 mm2
fine-wire without wire end ferrule: 1 x 0.75 ... 4 mm2
fine-wire with wire end ferrule: 1 x 0.5 ... 2.5 mm2
Installation width: 36 mm (2 HP)
Bus line
Nominal voltage: DC 12 V SELV
Current consumption: max. 20 mA
Bus connection: connection terminal
Cable length: max. 3 m