Further information for JUNG HOME blind actuator 1 way mini 2 binary inputs - BT J1 B2 U
Intended use
Manual and automatic control of blinds, roller shutters or awnings
Operation via binary inputs of the JUNG HOME actuator, JUNG HOME button, JUNG HOME sensors and JUNG HOME app
Querying conventional switching and touch contacts for reporting states, triggering scenes, operating consumers, etc.
Wireless linking with devices of the JUNG HOME system
Installation in device box with dimensions according to DIN 49073
Installation in false ceilings in the installation adapter mini housing (item no.: FM-EBG)
Product features
Commissioning and operation via JUNG HOME app with mobile device (smartphone or tablet) via Bluetooth®
Free linking of the 2 binary inputs with JUNG HOME actuators (local or wireless)
Independent use of actuator function and binary inputs
Multi-colored status display and Prog button for commissioning
Locking of the Prog button
Integration of the load in areas (groups), central functions and scenes
Up to 16 time programs
Ventilation position, running time, slat reversal time, reversal time adjustable for direction change and inverse operation
Activate/deactivate automatic functions via JUNG HOME app
Automatic date and time update when connected to smartphone
Bluetooth® SIG Mesh for fully encrypted wireless communication and repeater function
Updateable via JUNG HOME app
Available in the future via update:
(Information on updates and dates can be found at www.jung.de/JUNGHOME)
Time programs with sunrise or sunset (astrotimer)
Time programs with random time
Wind alarm via connection of conventional weather sensors to binary inputs
Trigger locking functions via binary inputs, e.g. lock-out protection for awnings, roller shutters and blinds, forced operation, etc.
Nominal voltage: AC 230 V ~
Mains frequency: 50/60 Hz
Standby power: max. 0.2 W
Power loss: max. 4 W
Ambient temperature: -5 ... +45 °C
Storage temperature: -5 ... +45 °C
Transport temperature: -25 ... +70 °C
Relative humidity: 20 ... 70 % (no Condensation)
Connected load
motors: 700 W
Installation depth: 20 mm
Accuracy per month: ± 13 s
Power reserve: at least 4 h
Cable length
load cable: max. 100 m
Binary input: max. 50 m
Dimensions (L x W x H): 48 x 51 x 20 mm
Connection outputs
single-wire: 1 x 0.5 ... 2.5 mm2
2 x 0.5 ... 2.5 mm2
fine-wire without wire end ferrule: 1 x 0.5 ... 4.0 mm2 2 x 0.5 ... 2.5 mm2
fine-wire with wire end ferrule: 1 x 0.5 ... 2.5 mm22 x 0.5 ... 1.5 mm2
Radio frequency: 2402.0 ... 2480.0 MHz
Transmission power: max. 10 mW (class 1.5)
Transmission range
in buildings: approx. 30 m