Further information for JUNG 1730JE
without extension input
for attachments Art. Nos.: .. 1700 .., .. 1701 .., .. 1750 D .., .. 1751 BT ..
Intended use
Control of electrically operated blinds, roller shutters and awnings
Automatic time control via attachment
Operation with suitable attachment from LB Management
Installation in device box in accordance with EN 60670-1
Product features
Automatic control via timer
Test operation for functional testing
Polarity reversal function of the outputs for simplified commissioning from version V01
Storage of a ventilation position via the attachment possible
Nominal voltage: AC 230 V ~
Mains frequency: 50/60 Hz
Ambient temperature: ?5 ... +45 °C
Contact type: µ
Standby power: max. 0.5 W
Running time: approx. 120 s
Connected load
motors: 700 W
Connection
Connection type: screw
terminals single-wire: 1 x 0.5 ... 4.0 mm2 2 x 0.5 ... 2.5 mm2
fine-stranded without wire end ferrule: 1 x 0.5 ... 4.0 mm2 2 x 0.5 ... 2.5 mm2
fine-stranded with wire end ferrule: 1 x 0.5 ... 4.0 mm22 x 0.5 ... 1.5 mm2