General
Rated transformation ratio100/1 A
Accuracy class1
Secondary power0,2 VA
Overload capacity60xIn/1s
Continuous overload capacity100%
Degree of protectionIP20
Protection classE
Max. temperature120 °C
Ambient temperature-5...+40 °C
Primary conductor max. diameter18 mm
Cable length3 m
Connection cable cross-section0,5 mm²
The cable current transformer KUW1/40 - 100/1A from Janitza is an industrial current transformer for use in electrical measurement and protection systems. It is designed to convert primary currents into proportional secondary currents, ensuring safe and precise supply to measuring instruments or protective devices. The device is specifically designed for mounting on cables, with the primary conductor having a maximum diameter of 18 mm inserted into the transformer. The unit is supplied with a permanently installed connection cable of length 3 m and cross-section 0.5 mm², directly connected to the secondary side.

Applications

The cable current transformer is intended for use in industrial and commercial electrical installations, particularly in systems with high current loads. It is typically used in switchgear, distribution systems, or for monitoring current circuits where non-invasive current measurement is required. The protection rating IP20 makes it suitable for indoor use, where there is no direct contact with water or dust. The ambient temperature range of -5 °C to +40 °C allows operation in standard industrial environments.

Functions and Equipment in Detail

The transformer features a nominal ratio of 100/1 A, meaning that a primary current of 100 A generates a secondary current of 1 A. The accuracy class 1 ensures high measurement accuracy, sufficient for requirements in industrial current measurement. The maximum overload capacity is 60 times the rated load for one second, allowing short-term overload during transient load peaks. The continuous overload capacity is specified as 100 %, meaning the transformer can be operated continuously at rated current. The secondary power is 0.2 VA, defining the transformer’s load capacity for connected measuring devices.

Technology Explained Simply

The cable current transformer operates on the principle of a transformer: the primary conductor, passed through the bore of the transformer, forms the primary winding. The secondary winding is integrated inside the transformer and generates a proportional current, which is tapped via the connected cable. The protection class E (max. 120 °C) refers to the maximum permissible temperature of the windings, describing the thermal load capacity of the device. The protection rating IP20 protects against finger contact and solid foreign objects, but not against water or dust.

Compatibility and Accessories

The cable current transformer is designed for use with measuring instruments, meters, or protective devices that can handle a secondary current of 1 A at 0.2 VA. It is not intended for direct connection to consumers or power switches. It is used in combination with suitable measuring devices that receive and evaluate the secondary current.

Mounting and Installation

Installation is performed by inserting the cable to be measured, with a maximum diameter of 18 mm, into the bore of the transformer. The device is installed at the desired position in the current circuit, with ambient temperature between -5 °C and +40 °C. The connected cable (3 m, 0.5 mm²) is attached to the secondary side and routed to the measuring instrument or protective device. Installation requires no additional tools, as the transformer is mounted directly onto the cable.

Advantages in Operation

The cable current transformer provides a simple and safe method for current measurement without interrupting the circuit. The high accuracy of class 1 and continuous overload capacity of 100 % ensure reliable measurement results even under load. The integrated cable connection with a length of 3 m enables flexible installation without requiring additional extensions or connection cables. The protection rating IP20 and temperature resistance up to 120 °C make the transformer suitable for use in standard industrial environments.