| General |
| Housing size | B 45 x H 73 x T 115 mm |
| Nominal power | 15 VA |
| Primary current | 5+5 A |
| Secondary current | 5 A |
| Accuracy of measurement | Kl.1 |
The Janitza IPS20 15VA 5+5/5A Kl.1 is a sum current transformer for use in industrial and energy technology applications. It is designed for measuring and monitoring electrical currents in three-phase AC systems, particularly in installations for energy distribution and metering. The device is intended for integration into switchboards and distribution boxes and enables precise capture of total currents from multiple individual currents. The term
sum current transformer describes its core function: the addition of multiple current components into a total current value, which is then available for measurement or protection systems.
Applications
The sum current transformer is used in industrial electrical engineering where precise capture of total current in a network is required. Typical application areas include energy distribution in production facilities, monitoring of electricity consumption in buildings, or integration into metering systems for Smart Grids. Class 1 (Kl.1) ensures high measurement accuracy, which is necessary for applications requiring high data quality.
Functions and Equipment in Detail
The transformer is designed for a rated power of 15 VA, which describes the maximum power it can deliver at rated load. The designation
5+5/5A refers to the current ratios: it features two primary windings, each for 5 A, which together can capture a total current of 10 A, and one secondary winding for 5 A. This configuration enables the addition of two current components, for example from two separate conductors, into a total current. Class 1 (Kl.1) guarantees a measurement deviation within ±1 % at rated load, which is crucial for precise measurements in energy technology.
Technology Explained Simply
A sum current transformer such as the IPS20 operates based on the principle of electromagnetic induction. The primary conductors carrying the current to be measured pass through the core of the transformer. This induces a proportional current in the secondary circuit, which is tapped off via a measuring resistor or a meter. The construction with two primary windings allows the addition of two current flows, which is useful, for example, when measuring current in a three-phase system using two conductors. The rated power of 15 VA defines the maximum load capacity of the secondary circuit to ensure stable and distortion-free measurement.
Compatibility and Accessories
The sum current transformer is designed for use in standard switchboards. The housing dimensions are W 45 mm × H 73 mm × D 115 mm, enabling installation in typical switchboards. It is used in conjunction with measuring instruments, meters, or protection systems capable of processing a secondary current of 5 A.
Mounting and Installation
Mounting is carried out in an enclosure or distribution box. The housing dimensions (W 45 mm × H 73 mm × D 115 mm) are designed for standard mounting positions. The primary conductors are routed through the core of the transformer, with the number of turns varying depending on the application. The secondary side is connected to a measuring instrument or meter. Installation does not require special tools, but proper wiring and secure fastening are necessary to ensure safe and reliable operation.
Advantages in Operation
The use of the Janitza IPS20 15VA 5+5/5A Kl.1 offers high measurement accuracy due to Class 1, which is critical for the reliability of energy consumption data. The construction with two primary windings enables flexible application for adding current components. The rated power of 15 VA ensures stable power supply for connected measuring devices. The compact design with dimensions W 45 mm × H 73 mm × D 115 mm allows efficient space utilisation in switchboards.