Further information for ifm Electronic UGT509 ultrasonic reflex sensor M18x1 IP67
Accessories
Scope of delivery
Mounting nuts: 2 x M18, stainless steel
Accuracy / Deviations
Hysteresis
< 2 %
Switching point drift
-2...2 %
Repeatability
1 %
Resolution
1 mm
Notes on accuracy / deviation
The specified values are achieved after a warm-up period of at least 20 minutes
Temperature compensation
Approvals / tests
EMC
EN 61000-4-2 ESD / 4 kV CD / 8 kV AD; EN 61000-4-3 Radiated HF / 3 V/m; EN 61000-4-4 Burst / 2 kV; EN 61000-4-6 Conducted HF / 3 V; EN 55011 / Class A
Vibration resistance
EN 60068-2-6 Fc / (10-55) Hz 1 mm amplitude, vibration duration 5 min., 30 min. per axis at resonance or 55 Hz
Shock resistance
EN 60068-2-27 Ea / 30 g 11 ms half-sine; 3 shocks in each direction of the 3 coordinate axes
MTTF
132 years
UL approval
Ta / -20...70 °C; Power supply / Class 2; UL file number / E174191
Detection range
Blind zone
150 mm
Opening angle cylindrical
15; (±2) °
Sensing range hysteresis
< 1 mm
Max. deviation from 90° angle sensor / object
± 4 °
Displays / controls
Indication
Switching state / 2 x LED, yellow; Echo / 1 x LED, green
Teach function
Electrical connection
Plug connection
1 x M12; coding: A; contacts: 4
Electrical data
Operating voltage
10...30 DC; ("supply class 2" according to cULus) V
Electricity consumption
55 mA
Protection class
III
Standby delay time
< 0,3 s
Converter frequency
230 kHz
Reverse polarity protection
Environmental conditions
Ambient temperature
-20...70 °C
Storage temperature
-30...80 °C
Degree of protection
IP 67
Inputs / Outputs
Number of inputs and outputs
Number of digital outputs: 2
Interfaces
Transmission type
COM2 (38.4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9
Profiles
Smart Sensor - SSP 0 / Generic Profiled Sensor; Function / Device identification; Function / Multiple switching signal; Function / Process data variable; Function / Device diagnosis; Function / Teach channel
Required master port class
A
Min. process cycle time
3,2 ms
IO-Link process data (cyclic)
Function / bit length; Process value / 16; Device status / 4; Binary switching information / 2
Normally open contact (NO) / Normally closed contact (NC); (configurable)
Switching distance
150...1600; (Target: 200 x 200 mm) mm
Communication interface
IO-Link
Housing
Threaded design
Dimensions
M18 x 1 / L = 97,5 mm
Remarks
Remarks
Operating voltage "supply class 2" according to cULus
Software / Programming
Parameterization options
Hysteresis / window; second switching point; make and break delay; switching operations; teach function; light/dark switching
The ultrasonic reflex sensor UGT509 from ifm Electronic is an industrial sensor in threaded design with a switching distance of 150 to 1600 mm, specified for a target object of 200 x 200 mm. It is used for non-contact detection of objects regardless of color, transparency, or surface condition. The electrical configuration is implemented as a PNP circuit, with the output function configurable as either a make or break contact. The operating voltage ranges from 10 to 30 V DC, and the power supply is classified as supply class 2 according to cULus. The current consumption is 55 mA, and the sensor features reverse polarity protection as well as a readiness delay time of less than 0.3 seconds.
Applications
The sensor is suitable for applications in automation technology, particularly in manufacturing industries, where reliable, non-contact object detection is required. It can be used in environments with high mechanical stress, such as vibrations or mechanical shocks, as it complies with standards EN 60068-2-6 and EN 60068-2-27. The protection rating IP 67 makes it suitable for outdoor use or in damp, dusty environments.
Functions and Equipment in Detail
The UGT509 features two digital outputs, each with a continuous current load capacity of 100 mA and a maximum voltage drop of 2.2 V. The switching frequency is 3 Hz, and the outputs are equipped with short-circuit protection and overload resistance. The status is indicated by two yellow LEDs for switching state and one green LED for echo. An integrated Teach function allows for easy adjustment of the detection range directly on the device.
Technology Explained Simply
The sensor operates using ultrasonic waves in the frequency range of 230 kHz. The wave is directed toward the target object, reflected, and received by the sensor. The time difference between transmission and reception is used to calculate the distance. The blind zone is 150 mm, meaning objects within this range cannot be detected. The beam angle is 15° (±2°), and the maximum deviation from the 90° angle between sensor and object is ±4°. The repeatability is 1 %, the resolution is 1 mm, and the hysteresis is less than 1 mm. Accuracy is achieved after a warm-up period of at least 20 minutes. Temperature compensation ensures stable measurement values across the operating temperature range of -20 to 70 °C.
Compatibility and Accessories
The sensor is equipped with IO-Link (Revision 1.1) and supports the profiles Smart Sensor - SSP 0 and Generic Profiled Sensor. Communication takes place via COM2 with a transmission rate of 38.4 kBaud. The required master port class is A, and the minimum process cycle time is 3.2 ms. IO-Link functions include cyclic process data (process value 16 bit, device status 4 bit, binary switching information 2 bit) as well as acyclic functions such as application-specific marking and operating hour counter. Supported DeviceIDs include, among others, the standard DeviceID 700. The connection is made via an M12 connector.
Mounting and Installation
The sensor has a threaded design M18 x 1 with a total length of 97.5 mm. The housing is made of stainless steel (1.4404 / 316L), PA, and epoxy glass-ceramic. The tightening torque is 50 Nm. The delivery includes two stainless steel mounting nuts M18.
Advantages in Operation
The sensor offers high reliability due to integrated temperature compensation and robust construction. Configurable functions such as hysteresis, window, second switching point, on/off delay, and light/dark switching allow flexible adaptation to different applications. The IO-Link interface enables centralized parameterization and diagnostics via the master, reducing maintenance and service effort. The MTTF is 132 years, indicating a long service life. Certifications according to EN 61000-4-2 to -4-6 and EN 55011 Class A ensure high electromagnetic compatibility. The UL certification (File Number E174191) confirms the safety of the power supply according to cULus.