The specified values are achieved after a warm-up period of at least 20 minutes
Temperature compensation
Approvals / tests
EMC
EN 61000-4-2 ESD / 4 kV CD / 8 kV AD; EN 61000-4-3 Radiated HF / 3 V/m; EN 61000-4-4 Burst / 2 kV; EN 61000-4-6 Conducted HF / 3 V; EN 55011 / Class A
Vibration resistance
EN 60068-2-6 Fc / (10-55) Hz 1 mm amplitude, vibration duration 5 min., 30 min. per axis at resonance or 55 Hz
Shock resistance
EN 60068-2-27 Ea / 30 g 11 ms half-sine; 3 shocks in each direction of the 3 coordinate axes
MTTF
838 years
UL approval
Ta / -10...70 °C; Enclosure type / Type 1; Power supply / Class 2; File Number UL / E174191
Detection range
Blind zone
50 mm
Opening angle cylindrical
16; (±1) °
Max. deviation from 90° angle sensor / object
± 4 °
Displays / controls
Indication
Switching state / 1 LED, yellow
Electrical connection - Plug
Plug connection
1 x M12; coding: A; contacts: 4
Electrical data
Operating voltage
10...30 DC; (supply voltage "supply class 2" according to cULus) V
Electricity consumption
< 50 mA
Protection class
III
Standby delay time
< 0,5 s
Converter frequency
300 kHz
Reverse polarity protection
Environmental conditions
Ambient temperature
-10...70 °C
Storage temperature
-25...75 °C
Degree of protection
IP 65; IP 67; IP 68; IP 69K
Inputs / Outputs
Number of inputs and outputs
Number of digital outputs: 1; Number of analog outputs: 1
Interfaces
Transmission type
COM2 (38.4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9
Profiles
Smart Sensor - SSP 4.1.1 / Measuring and Switching Sensor, 1 channel; Common - I&D / Identification and Diagnosis; Extension / Sensor control; Extension / Object detection, switches when value falls below the setpoint; Function / Locator; Function / ProductURI
Required master port class
A
Min. process cycle time
3,2 ms
IO-Link process data (cyclic)
Function / bit length; Process value / 16; Device status / 4; Binary switching information / 2
Further information can be found in the IODD-PDF file under "Downloads"
SIO mode
Mechanical data
Thread designation
M18 x 1
Materials
Housing: 1.4404 (stainless steel / 316L); LED window: PA
Tightening moment
50 Nm
Outputs
Total number of outputs
2
Number of digital outputs
1
Max. voltage drop switching output DC
2,2 V
Continuous current rating of switching output DC
100 mA
Switching frequency DC
10 Hz
Number of analogue outputs
1
Analog output voltage
0...10 V
Minimum load resistance
3000 Ω
Short-circuit protection
Overload resistant
Product features
Electrical version
PNP/NPN; (configurable)
Output function
Normally open contact (NO) / Normally closed contact (NC); (configurable)
Switching distance
50...400; (Target: 100 x 100 mm) mm
Communication interface
IO-Link
Housing
Threaded design
Dimensions
M18 x 1 / L = 98,5 mm
Response times
Response time
< 600; (analogue output) ms
Software / Programming
Parameterization options
Hysteresis / window; second switching point; make and break delay; switching operations; teach function; light/dark switching
Ultraschallreflextaster, M18 x 1 / L = 98,5 mm, Schaltabstand 50...400, (Target: 100 x 100 mm), Schließer / Öffner, (parametrierbar), analog, DC, PNP/NPN, M12 Steckverbindung, IP 65, IP 67, IP 68, IP 69K, Umgebungstemperatur -10...70 °C