Further information for ifm Electronic TW2101 infrared temperature sensor PNP IO-Link
Accessories
Scope of delivery
Fastening nuts: 2
Accuracy / Deviations
Accuracy
< ± 0.5 %; (of measured value, minimum 4 K (emissivity = 1, T = 23°C)) K
Repeatability
1 K
Approvals / tests
EMC
DIN EN 61000-6-2; DIN EN 61000-6-4
Shock resistance
DIN EN 60068-2-27 / 30 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 / 5 g (10...2000 Hz)
MTTF
71 years
Detection range
Wavelength range
1...1,7 µm
Displays / controls
Indication
Display unit / 2 x LED, yellow; Switching state / 1 x LED, yellow; Function indicator / 7-segment LED display, 4-digit; Measured values / 7-segment LED display, 4-digit; Adjustment aid / LED pilot light, green
Smart Sensor - SSP 0 / Generic Profiled Sensor; Function / Device identification; Function / Process data variable; Function / Device diagnosis
Required master port class
A
Analog process data
16
Process data binary
1
Min. process cycle time
3,6 ms
Supported DeviceIDs
Operating mode / DeviceID; default / 717
SIO mode
Measurement / adjustment range
Switching point SP
251...1600 °C / 484...2912 °F
Reverse switch point rP
250...1599 °C / 482...2910 °F
Analog start point
250...1400 °C / 482...2552 °F
Analog endpoint
450...1600 °C / 842...2912 °F
In steps of
1 °C / 1 °F
Resolution of switching output
1 K
Analog output resolution
0.2; (+ 0.03 % of set measurement span) K
Display resolution
1 K
Mechanical data
Housing
Threaded design
Dimensions
M30 x 1,5 / L = 239,5 mm
Thread designation
M30 x 1.5
Materials
Threaded bushing: 1.4305 (stainless steel / 303); control panel: polyester
Optic material
Front glass: tempered optical glass
Outputs
Total number of outputs
2
Output signal
Switching signal; analog signal; IO-Link; (configurable)
Electrical version
PNP
Number of digital outputs
1
Output function
Normally open contact (NO) / Normally closed contact (NC); (configurable)
Max. voltage drop switching output DC
2,5 V
Continuous current rating of switching output DC
150 mA
Number of analogue outputs
1
Analog output current
4...20 mA
Max. load
500 Ω
Short-circuit protection type
timed
Short-circuit protection
Short-circuit-proof
Overload resistant
Product features
Number of inputs and outputs
Number of digital outputs: 1; Number of analog outputs: 1
Measuring range
250...1600 °C / 482...2912 °F
Communication interface
IO-Link
Remarks
Remarks
To keep electrical and/or magnetic fields away from the infrared temperature sensor, a shielded cable must be used. The shield must be connected to the housing via the plug housing.
Response times
Response time
2; (T > 600 °C) ms
Software / Programming
Switching point adjustment
Programming keys
Parameterization options
Analog range; normally open contact (NO) / normally closed contact (NC); pickup/dropout delay; damping; peak hold; emissivity; simulation function
Infrarot-Temperatursensor, M30 x 1,5 / L = 239,5 mm, PNP, 250...1600 °C, Schließer / Öffner, (parametrierbar), analog