Accuracy / Deviations Switching point accuracy ± 0,3 K Temperature influence per 10 K 0,1 **) K Approvals / tests EMC DIN EN 61000-6-2; DIN EN 61000-6-3 Shock resistance DIN IEC 68-2-27 / 50 g (11 ms) Vibration resistance DIN EN 60068-2-6 / 20 g (10...2000 Hz) MTTF 543 years UL approval UL Listing Number / K019 Electrical connection Plug connection 1 x M12; Coding: A; Contacts: 4, gold-plated Electrical data Operating voltage 18...32 DC; ("supply class 2" according to cULus) V Electricity consumption < 50 mA Protection class III Standby delay time 1 s Reverse polarity protection Yes Integrated watchdog Yes Environmental conditions Ambient temperature -40...80 °C Note on ambient temperature At medium temperature: < 125 °C; -40...50 °C; at medium temperature: < 150 °C Storage temperature -40...100 °C Degree of protection IP 69K Field of application Special feature Gold-plated contacts Measuring element 1 x Pt 1000; (according to DIN EN 60751, Class A) Media Liquid and gaseous media Compressive strength 300 bar / 30 MPa Note on pressure resistance Sensor; when installed in adapter, adapter specifications apply. Interfaces Transmission type COM2 (38.4 kBaud) IO-Link revision 1.1 Profiles Smart Sensor - SSP 0 / Generic Profiled Sensor; Function / Device identification; Function / Process data variable; Function / Device diagnosis Min. process cycle time 3,2 ms Supported DeviceIDs Operation mode / DeviceID; default / 733 Measurement / adjustment range Rod length L 16 mm Switching point SP -49,8...150 °C Reverse switch point rP -50...149,8 °C In steps of 0.1 °C Resolution of switching output 0,1 K Mechanical data Housing Cylindrical Dimensions Ø 18,7 / L = 93,9 mm Materials 1.4404 (stainless steel / 316L); FKM Materials in contact with the medium 1.4404 (stainless steel / 316L); O-ring: FKM Tightening moment 45 Nm Rod diameter 6 mm Outputs Total number of outputs 2 Output signal Switching signal; IO-Link; (configurable) Electrical version PNP/NPN Number of digital outputs 2 Output function Normally open contact (NO) / Normally closed contact (NC); (configurable) Max. voltage drop switching output DC 2,5 V Continuous current rating of switching output DC 100 mA Product features Number of inputs and outputs Number of digital outputs: 2 Measuring range -50...150 °C Communication interface IO-Link Process connection Threaded connection G 1/2 male thread Installation length EL 30 mm Remarks Remarks The accuracy values apply to moving water. Response times Response dynamics T05 / T09 1 / 3; (according to DIN EN 60751) s Software / Programming Parameterization options Hysteresis / window; Normally open contact (NO) / Normally closed contact (NC); Switching logic; Switching / reset delay; Damping; Display unit
Transmitter mit IO-Link, 1 x Pt 1000, (nach DIN EN 60751, Klasse A), PNP/NPN, Schaltsignal, IO-Link, Einbaulänge EL 30 mm, Messbereich -50...150 °C, Druckfestigkeit 300 bar, G 1/2 Außengewinde, M12 Steckverbindung