| Accuracy / Deviations |
| Accuracy | ± (0,15 K + 0,002 x|t|) K |
| Approvals / tests |
| Shock resistance | DIN EN 60068-2-27 / 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6 / 10 g (10...2000 Hz) |
| MTTF | 22831 years |
| UL approval | UL Listing Number / K004; File Number UL / E217884 |
| Electrical connection |
| Plug connection | 1 x M12; Coding: A; Contacts: 4, gold-plated |
| Electrical data |
| Protection class | III |
| Environmental conditions |
| Ambient temperature | -25...80 °C |
| Storage temperature | -40...100 °C |
| Degree of protection | IP 68; IP 69K |
| Field of application |
| Special feature | Gold-plated contacts |
| Measuring element | 1 x Pt 100; (according to DIN EN 60751, Class A) |
| Application | Hygiene area |
| Media | Liquid and gaseous media |
| Compressive strength | 160 bar / 16 MPa |
| Minimum immersion depth | 15 mm |
| Measurement / adjustment range |
| Rod length L | 100 mm |
| Mechanical data |
| Housing | Cylindrical |
| Dimensions | Ø 6 / L = 124 mm |
| Materials | 1.4404 (stainless steel / 316L) |
| Materials in contact with the medium | 1.4404 (stainless steel / 316L) electropolished |
| Surface roughness Ra/Rz of medium-contacting surfaces | Ra < 0,8 µm |
| Rod diameter | 6 mm |
| Product features |
| Measuring range | -40...150 °C / -40...302 °F |
| Process connection | Terminal adaptation Ø 6 mm |
| Installation length EL | 100 mm |
| Remarks |
| Remarks | Operating voltage "supply class 2" according to cULus; The values for accuracy apply to moving water. |
| Response times |
| Response dynamics T05 / T09 | 1 / 3; (according to DIN EN 60751) s |
Temperature sensor for connection to evaluation unit, 1 x Pt 100, (according to DIN EN 60751, Class A), installation length EL 100 mm, measuring range -40...150 °C / -40...302 °F, pressure resistance 160 bar, diameter Ø 6 mm, M12 plug connection