| Accuracy / Deviations |
| Accuracy | ± (0,15 K + 0,002 x|t|) K |
| Approvals / tests |
| MTTF | 11416 years |
| Electrical connection |
| Cable | 2 m, PUR |
| Plug connection | 1 x M12; Coding: A; Contacts: 4, gold-plated |
| Electrical data |
| Protection class | III |
| Environmental conditions |
| Degree of protection | IP 67 |
| Field of application |
| Special feature | Gold-plated contacts |
| Measuring element | 1 x Pt 1000; (according to DIN EN 60751, Class A) |
| Media | Liquid and gaseous media |
| Compressive strength | 160 bar / 16 MPa |
| Minimum immersion depth | 15 mm |
| Mechanical data |
| Housing | Cylindrical |
| Construction type | Sensor |
| Dimensions | Ø 10 / L = 50 mm |
| Materials | Stainless steel |
| Materials in contact with the medium | 1.4404 (stainless steel / 316L) |
| Rod diameter | 10 mm |
| Product features |
| Measuring range | -40...90 °C / -40...194 °F |
| Process connection | Terminal adaptation Ø 10 mm |
| Installation length EL | 42 mm |
| Remarks |
| Remarks | The accuracy values apply to moving water. |
| Response times |
| Response dynamics T05 / T09 | 6 / 25; (according to DIN EN 60751) s |
Temperatursensor zum Anschluss an Auswerteeinheit, 1 x Pt 1000, (nach DIN EN 60751, Klasse A), Einbaulänge EL 42 mm, Messbereich -40...90 °C, -40...194 °F, Druckfestigkeit 160 bar, Klemmadaption Ø 10 mm, 2 m PUR-Kabel, M12 Steckverbindung