Further information for ifm Electronic TCC831 temperature transmitter Pt1000 PNP/NPN
Accuracy / Deviations
Accuracy of analogue output
± 0,2 K
IO-Link accuracy
± 0,2 K
Temperature coefficient analogue output
< ± 0.02; (At deviation from reference condition 25 ± 5 °C) % of span / 10 K
Temperature coefficient IO-Link
< ± 0.01; (deviation from reference condition 25 ± 5 °C) % of span / 10 K
Approvals / tests
EMC
DIN EN 61000-6-2; DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-27 / 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 / 35 g (10...2000 Hz)
MTTF
329 years
Note on approval
Factory certificate available for download at www.factory-certificate.ifm
UL approval
Approval number UL / K021; File number UL / E217884
Electrical connection
Plug connection
1 x M12; Coding: A; Contacts: 4, gold-plated
Electrical data
Operating voltage
18...32 DC; ("supply class 2" according to cULus) V
Electricity consumption
10; (24 V) mA
Protection class
III
Standby delay time
6 s
Reverse polarity protection
Integrated watchdog
Environmental conditions
Ambient temperature
-25...70 °C
Note on ambient temperature
max. internal device temperature: 125 °C
Storage temperature
-40...100 °C
Degree of protection
IP 68; IP 69K
Field of application
Special feature
Gold-plated contacts
Measuring element
1 x Pt 1000
Reference element
1 x NTC
Media
Liquid and gaseous media
Compressive strength
160 bar / 16 MPa
Minimum immersion depth
15 mm
Interfaces
Transmission type
COM2 (38.4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9 CDV
Profiles
BLOB / Binary Large Object transfer; Common - I&D / Identification and Diagnosis; Function / Measurement data, standard resolution
Required master port class
A
Analog process data
1
Process data binary
1
Min. process cycle time
4,4 ms
IO-Link resolution temperature
0,01 K
Supported DeviceIDs
Operating mode / DeviceID; default / 1129
SIO mode
Measurement / adjustment range
Rod length L
100 mm
Note on measurement range
scalable
Factory setting
-10...150 °C / 14...302 °F
Calibration check limit
0,5...3 K
In steps of
0,05 K
Analog output resolution
0,05 K
Mechanical data
Housing
Cylindrical
Dimensions
Ø 50 / L = 164,8 mm
Materials
1.4404 (stainless steel / 316L); PEI; FKM; PFA
Materials in contact with the medium
1.4404 (stainless steel / 316L); PEEK
Suitable for process connection standard
DIN 32676 Series A (DIN) / Clamp DN25, DN32, DN40; DIN 32676 Series B (ISO) / Clamp DN21.3, DN26.9, DN33.7; DIN 32676 Series C (ASME BPE) / Clamp 1", 1.5"; ISO 2852 / Clamp DN25, DN33.7, DN38
Surface roughness Ra/Rz of medium-contacting surfaces
Ra < 0,8 µm
Rod diameter
6 mm
Outputs
Total number of outputs
2
Output signal
Analog signal; IO-Link; (calibration check status)
Electrical version
PNP/NPN
Number of digital outputs
1
Output function
Normally closed contact (NC); (Diagnostic signal)
Max. voltage drop switching output DC
2 V
Continuous current rating of switching output DC
100 mA
Diagnostic output
Calibration check status and fault diagnosis
Number of analogue outputs
1
Analog output current
4...20 mA
Max. load
(Ub - 15 V) x 50 Ω
Short-circuit protection type
timed
Short-circuit protection
Overload resistant
Product features
Number of inputs and outputs
Number of digital outputs: 1; Number of analog outputs: 1
Measuring range
-25...160 °C / -13...320 °F
Communication interface
IO-Link
Process connection
Clamp DN25...DN40 (1...1.5") DIN 32676 (ISO 2852)
Installation length EL
100 mm
Remarks
Remarks
MS = set measurement range; supply voltage "supply class 2" according to cULus