Accuracy / Deviations Accuracy of analogue output ± 0,2 K IO-Link accuracy ± 0,2 K Temperature coefficient analogue output < ± 0.02; (At deviation from reference condition 25 ± 5 °C) % of span / 10 K Temperature coefficient IO-Link < ± 0.01; (deviation from reference condition 25 ± 5 °C) % of span / 10 K Approvals / tests EMC DIN EN 61000-6-2; DIN EN 61000-6-3 Shock resistance DIN EN 60068-2-27 / 50 g (11 ms) Vibration resistance DIN EN 60068-2-6 / 35 g (10...2000 Hz) MTTF 329 years Electrical connection Plug connection 1 x M12; Coding: A; Contacts: 4, gold-plated Electrical data Operating voltage 18...32 DC; ("supply class 2" according to cULus) V Electricity consumption 10; (24 V) mA Protection class III Standby delay time 6 s Reverse polarity protection Yes Integrated watchdog Yes Environmental conditions Ambient temperature -25...70 °C Note on ambient temperature max. internal device temperature: 125 °C Storage temperature -40...100 °C Degree of protection IP 68; IP 69K Field of application Special feature Gold-plated contacts Measuring element 1 x Pt 1000 Reference element 1 x NTC Mounting For use in hygienic applications, a protective sleeve is required Media Liquid and gaseous media Compressive strength 160 bar / 16 MPa Minimum immersion depth 15 mm Interfaces Transmission type COM2 (38.4 kBaud) IO-Link revision 1.1 SDCI standard IEC 61131-9 CDV Profiles BLOB / Binary Large Object transfer; Common - I&D / Identification and Diagnosis; Function / Measurement data, standard resolution Required master port class A Analog process data 1 Process data binary 1 Min. process cycle time 4,4 ms IO-Link resolution temperature 0,01 K Supported DeviceIDs Operating mode / DeviceID; default / 1129 SIO mode Yes Measurement / adjustment range Rod length L 1000 mm Note on measurement range scalable Factory setting -10...150 °C / 14...302 °F Calibration check limit 0,5...3 K In steps of 0,05 K Analog output resolution 0,05 K Mechanical data Housing Cylindrical Dimensions Ø 50 / L = 1094 mm Materials 1.4404 (stainless steel / 316L); PEI; FKM; PFA Materials in contact with the medium 1.4404 (stainless steel / 316L) Tightening moment 30...50 Nm Rod diameter 6 mm Outputs Total number of outputs 2 Output signal Analog signal; IO-Link; (calibration check status) Electrical version PNP/NPN Number of digital outputs 1 Output function Normally closed contact (NC); (Diagnostic signal) Max. voltage drop switching output DC 2 V Continuous current rating of switching output DC 100 mA Diagnostic output Calibration check status and fault diagnosis Number of analogue outputs 1 Analog output current 4...20 mA Max. load (Ub - 15 V) x 50 Ω Short-circuit protection type timed Short-circuit protection Yes Overload resistant Yes Product features Number of inputs and outputs Number of digital outputs: 1; Number of analog outputs: 1 Measuring range -25...160 °C / -13...320 °F Communication interface IO-Link Process connection Threaded connection G 1/2 male thread sealing cone Installation length EL 1000 mm Remarks Remarks MS = set measurement range; supply voltage "supply class 2" according to cULus Response times Response dynamics T05 / T09 1,5 / 4 s Software / Programming Parameterization options Display unit; scaling analog output; calibration check limit; switching logic diagnostic output; simulation mode
Temperaturtransmitter, 1 x Pt 1000, PNP/NPN, Analogsignal, IO-Link, Einbaulänge EL 1000 mm, Messbereich -25...160 °C, -13...320 °F, Werkseinstellung -10...150 °C / 14...302 °F, Druckfestigkeit 160 bar, G 1/2 Außengewinde Dichtkonus, M12 Steckverbindung