Further information for ifm Electronic TA2417 temperature transmitter Pt1000
Accuracy / Deviations
Accuracy of analogue output
± 0,3 + (± 0,1 % MS) K
Temperature coefficient
0.1; (At deviation from reference condition 25 ± 5 °C) % of span / 10 K
Approvals / tests
EMC
DIN EN 61000-6-2
Shock resistance
DIN IEC 68-2-27 / 50 g (11 ms)
Vibration resistance
DIN IEC 68-2-6 / 20 g (10...2000 Hz)
MTTF
230 years
UL approval
UL Listing Number / K002
Displays / controls
Indication
Operating status / 1 x LED, green
Electrical connection
Plug connection
1 x M12; Coding: A; Contacts: 4, gold-plated
Electrical data
Operating voltage
18...32 DC; ("supply class 2" according to cULus) V
Electricity consumption
< 50 mA
Protection class
III
Standby delay time
1 s
Reverse polarity protection
Environmental conditions
Ambient temperature
-25...80 °C
Storage temperature
-40...100 °C
Degree of protection
IP 67; IP 68; IP 69K
Field of application
Special feature
Gold-plated contacts
Measuring element
1 x Pt 1000; (according to DIN EN 60751, Class A)
Media
Liquid and gaseous media
Compressive strength
300 bar / 30 MPa
Note on pressure resistance
Sensor; when installed in adapter, adapter specifications apply.
Interfaces
Transmission type
COM2 (38.4 kBaud)
IO-Link revision
1.1
Profiles
Smart Sensor - SSP 0 / Generic Profiled Sensor; Function / Device identification; Function / Process data variable
Min. process cycle time
2,3 ms
Supported DeviceIDs
Operation mode / DeviceID; default / 559
Measurement / adjustment range
Rod length L
36 mm
Factory setting
0...100 °C
Analog output resolution
0,04 K
Mechanical data
Housing
Cylindrical
Dimensions
Ø 18,7 / L = 113,9 mm
Materials
1.4404 (stainless steel / 316L); PEI; FKM
Materials in contact with the medium
1.4404 (stainless steel / 316L); O-ring: FKM
Tightening moment
45 Nm
Rod diameter
6 mm
Outputs
Total number of outputs
1
Output signal
Analogue signal; IO-Link; (configurable)
Number of analogue outputs
1
Analog output current
4...20 mA
Max. load
250; ((18...19 V); 19...32 V: 300 Ω) Ω
Short-circuit protection
Overload resistant
Product features
Number of inputs and outputs
Number of analog outputs: 1
Measuring range
-50...150 °C
Communication interface
IO-Link
Process connection
Threaded connection G 1/2 male thread
Installation length EL
50 mm
Remarks
Remarks
MS = set measurement range
Response times
Response dynamics T05 / T09
1 / 3 s
Temperaturtransmitter, 1 x Pt 1000, (nach DIN EN 60751, Klasse A), Analogsignal, IO-Link, Einbaulänge EL 50 mm, Messbereich -50...150 °C, Werkseinstellung 0...100 °C, Druckfestigkeit 300 bar, G 1/2 Außengewinde, M12 Steckverbindung