| Accuracy / Deviations |
| Accuracy of analogue output | ± 0,3 + (± 0,1 % MS) K |
| Temperature coefficient | 0.1; (At deviation from reference condition 25 ± 5 °C) % of span / 10 K |
| Approvals / tests |
| EMC | DIN EN 61000-6-2 |
| Shock resistance | DIN IEC 68-2-27 / 50 g (11 ms) |
| Vibration resistance | DIN IEC 68-2-6 / 20 g (10...2000 Hz) |
| MTTF | 572 years |
| UL approval | UL Listing Number / K002 |
| Displays / controls |
| Indication | Operating status / 1 x LED, green |
| Electrical connection |
| Plug connection | 1 x M12; Coding: A; Contacts: 4, gold-plated |
| Electrical data |
| Operating voltage | 18...32 DC; ("supply class 2" according to cULus) V |
| Electricity consumption | < 50 mA |
| Protection class | III |
| Standby delay time | 1 s |
| Reverse polarity protection | |
| Environmental conditions |
| Ambient temperature | -25...80 °C |
| Storage temperature | -40...100 °C |
| Degree of protection | IP 67; IP 68; IP 69K |
| Field of application |
| Special feature | Gold-plated contacts |
| Measuring element | 1 x Pt 1000; (according to DIN EN 60751, Class A) |
| Media | Liquid and gaseous media |
| Compressive strength | 400 bar / 40 MPa |
| Note on pressure resistance | Sensor; when installed in adapter, adapter specifications apply. |
| Interfaces |
| Transmission type | COM2 (38.4 kBaud) |
| IO-Link revision | 1.1 |
| Profiles | Smart Sensor - SSP 0 / Generic Profiled Sensor; Function / Device identification; Function / Process data variable |
| Min. process cycle time | 2,3 ms |
| Supported DeviceIDs | Operation mode / DeviceID; default / 377 |
| Measurement / adjustment range |
| Rod length L | 12 mm |
| Factory setting | -50...150 °C |
| Analog output resolution | 0,04 K |
| Mechanical data |
| Housing | Cylindrical |
| Dimensions | Ø 18,7 / L = 88,9 mm |
| Materials | 1.4404 (stainless steel / 316L); PEI; FKM |
| Materials in contact with the medium | 1.4404 (stainless steel / 316L); O-ring: FKM |
| Tightening moment | 35 Nm |
| Rod diameter | 6 mm |
| Outputs |
| Total number of outputs | 1 |
| Output signal | Analogue signal; IO-Link; (configurable) |
| Number of analogue outputs | 1 |
| Analog output current | 4...20 mA |
| Max. load | 250; ((18...19 V); 19...32 V: 300 Ω) Ω |
| Short-circuit protection | |
| Overload resistant | |
| Product features |
| Number of inputs and outputs | Number of analog outputs: 1 |
| Measuring range | -50...150 °C |
| Communication interface | IO-Link |
| Process connection | Threaded connection G 1/4 male thread |
| Installation length EL | 25 mm |
| Remarks |
| Remarks | MS = set measurement range |
| Response times |
| Response dynamics T05 / T09 | 1 / 3 s |
Temperature transmitter, DC, Analogue output 4...20 mA, Connector
Application: liquids and gases
Process connection: G ¼
Operating voltage: 18...32 V DC
Electrical design: DC
Output function: 4...20 mA analogue
Installation length EL: 25 mm
Factory setting: -50...150 °C
Dynamic response: 1 / 3 T05 / T09 s
Connection: M12 connector
Housing materials: stainless steel 316L / 1.4404; PEI; FKM
Materials (wetted parts): stainless steel 316L / 1.4404; O-ring: FKM
Ambient temperature: -25...80 °C
Protection: IP 67 / IP 68 / IP 69K
Display: operating status: 1 x LED green
Accessories (to be ordered separately): Socket, Mounting accessories
Type: TA2105