| Accessories |
| Scope of delivery | Sticker |
| Accuracy / Deviations |
| Accuracy (within measurement range) | ± (0.8 % MW + 0.5 % MEW) |
| Repeatability | ± 0.2% of measured value |
| Temperature drift | ± 0,0185 °F / K |
| Accuracy | ± 1 (77 °F; Q > 4 gpm) K |
| Approvals / tests |
| EMC | DIN EN 60947-5-9 |
| Shock resistance | DIN EN 60068-2-27 / 20 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6 / 5 g (10...2000 Hz) |
| MTTF | 85 years |
| UL approval | Approval number UL / I008; File number UL / E174189 |
| Printer directive | Good engineering practice; suitable for fluids of group 2; fluids of group 1 on request |
| Displays / controls |
| Indication | Display unit / 6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³); Switching state / 2 x LED, yellow; Measured values / alphanumeric display, 4-digit; Programming / alphanumeric display, 4-digit |
| Electrical connection |
| Plug connection | 1 x M12; Coding: A; Contacts: 4, gold-plated |
| Electrical data |
| Operating voltage | 18...32 DC; (according to SELV/PELV) V |
| Electricity consumption | < 150 mA |
| Protection class | III |
| Standby delay time | 5 s |
| Measurement principle | Magnetic-inductive |
| Reverse polarity protection | |
| Environmental conditions |
| Ambient temperature | 14...140 °F |
| Storage temperature | -13...176 °F |
| Degree of protection | IP 65; IP 67 |
| Field of application |
| Special feature | Gold-plated contacts |
| Application | Totaliser function; Empty pipe detection; for industrial use |
| Media | Conductive liquid media; water; water-based media |
| Media note | Conductivity: ≥ 20 µS/cm; Viscosity: < 70 mm²/s (40 °C) |
| Medium temperature | 14...194 °F |
| Compressive strength | 16 bar / 1.6 MPa |
| MAWP for applications according to CRN | 8.9 bar / 0.89 MPa |
| Inputs |
| Inputs | Counter reset |
| Interfaces |
| Communication interface | IO-Link |
| Transmission type | COM2 (38.4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 CDV |
| Profiles | Smart Sensor - SSP 0 / Generic Profiled Sensor; Function / Device identification; Function / Process data variable |
| Required master port class | A |
| Analog process data | 3 |
| Process data binary | 2 |
| Min. process cycle time | 5 ms |
| Supported DeviceIDs | Operation mode / DeviceID; default / 392 |
| SIO mode | |
| Measurement / adjustment range |
| Display range | -5760...5760 gph / -96...96 gpm |
| Resolution | 5 gph / 0.1 gpm |
| Switching point SP | 105...4800 gph / 1.7...80 gpm |
| Reverse switch point rP | 80...4775 gph / 1.3...79.6 gpm |
| Analog start point ASP | 0...3840 gph / 0...64 gpm |
| Analog endpoint AEP | 960...4800 gph / 16...80 gpm |
| Low flow cut-off LFC | < 240 gph / < 4 gpm |
| Step size | 5 gph / 0.1 gpm |
| Measurement dynamic range | 1:60 |
| Pulse value | 0.02...80 E06 gal |
| In steps of | 0.02 gal |
| Pulse duration | 0,016...2 s |
| Analog start point | -4...140 °F |
| Analog endpoint | 32...176 °F |
| Mechanical data |
| Housing | rectangular |
| Entry length | 3 x DN |
| Release distance | 1 x DN |
| Dimensions | 170 x 103 x 117 mm |
| Materials | 1.4404 (Stainless steel / 316L); 1.4571 (Stainless steel / 316Ti); PEI; FKM; PBT-GF20; TPE-U |
| Materials in contact with the medium | 1.4404 (stainless steel / 316L); 1.4571 (stainless steel / 316Ti); PEEK; FKM |
| Outputs |
| Total number of outputs | 2 |
| Output signal | Switching signal; Analog signal; Pulse signal; Frequency signal; IO-Link; (configurable) |
| Electrical version | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | Normally open contact (NO) / Normally closed contact (NC); (configurable) |
| Max. voltage drop switching output DC | 2 V |
| Continuous current rating of switching output DC | 250; (per output) mA |
| Number of analogue outputs | 1 |
| Analog output current | 4...20; (scalable) mA |
| Max. load | 500 Ω |
| Analog output voltage | 0...10; (scalable) V |
| Minimum load resistance | 2000 Ω |
| Pulse output | flow meter |
| Short-circuit protection type | timed |
| Output frequency | 0,1...10000 Hz |
| Short-circuit protection | |
| Overload resistant | |
| Product features |
| Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
| Measuring range | 80...4800 gph / 1.3...80 gpm |
| Process connection | Threaded connection 1 1/2" NPT internal thread DN40 |
| Remarks |
| Remarks | MW = measured value; MEW = end value of measurement range |
| Response times |
| Response time | 0.35; (dAP = 0) s |
| Adjustable delay time dS, dr | 0...50 s |
| Process value damping dAP | 0...5 s |
| Response dynamics T05 / T09 | T09 = 3 (Q > 4 gpm) s |
| Software / Programming |
| Parameterization options | Flow monitoring; metering; preset counter; temperature monitoring; hysteresis / window; normally open contact (NO) / normally closed contact (NC); switching logic; current/voltage/frequency/pulse output; start-up bypass time; display switchable off; display unit; empty tube detection |
Magnetisch-induktiver Durchflusssensor, PNP/NPN, Schaltsignal, Analogsignal, Impulssignal, Frequenzsignal, IO-Link, Druckfestigkeit 16 bar, 1 1/2' NPT Innengewinde DN40, Steckverbindung