| Accuracy / Deviations |
| Repeatability | 1...5 cm/s |
| Note on repeatability | For water 5...100 cm/s; 25 °C; factory setting |
| Temperature drift | 0.1; (for water 5...100 cm/s; 10...70 °C) cm/s x 1/K |
| Temperature gradient | 300 K/min |
| Switching point accuracy | ± 2...± 10; (for water 5...100 cm/s; 25 °C; factory setting) cm/s |
| Hysteresis | 2...5; (for water 5...100 cm/s; 25 °C; factory setting) cm/s |
| Approvals / tests |
| EMC | EN 61000-4-2 ESD / 4 kV CD / 8 kV AD; EN 61000-4-3 Radiated HF / 10 V/m; EN 61000-4-4 Burst / 2 kV; EN 61000-4-6 Conducted HF / 10 V |
| Shock resistance | DIN IEC 68-2-27 / 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6 / 10 g (55...2000 Hz) |
| MTTF | 298 years |
| Displays / controls |
| Indication | Function / 10 x LED, 3-colour |
| Electrical connection |
| Plug connection | 1 x M12; Coding: A; Contacts: 4, gold-plated |
| Electrical data |
| Operating voltage | 19...36 DC V |
| Electricity consumption | < 60 mA |
| Protection class | III |
| Standby delay time | 10 s |
| Reverse polarity protection | |
| Environmental conditions |
| Ambient temperature | -25...60 °C |
| Degree of protection | IP 67; IP 69K |
| Field of application |
| Special feature | Gold-plated contacts |
| Application | Hygiene area |
| Medium temperature | -25...95; (for SIP process: ...140 °C) °C |
| Compressive strength | 30 bar / 3 MPa |
| Measurement / adjustment range |
| Rod length L | 38 mm |
| Adjustment range | 3...300 cm/s |
| Maximum sensitivity | 3...100 cm/s |
| Mechanical data |
| Housing | Cylindrical |
| Dimensions | Ø 50 / L = 137 mm |
| Materials | 1.4404 (stainless steel / 316L); PC; PBT-GF20; EPDM/X; O-ring: FKM |
| Materials in contact with the medium | 1.4435 (Stainless steel / 316L) Surface finish: Ra < 0.4 µm / Rz = 4 µm |
| Rod diameter | 7,7 mm |
| Installation length EL | 38 mm |
| Outputs |
| Total number of outputs | 1 |
| Output signal | Switching signal |
| Electrical version | PNP |
| Number of digital outputs | 1 |
| Output function | Normally open contact (NO) / Normally closed contact (NC); (configurable) |
| Max. voltage drop switching output DC | 2,5 V |
| Continuous current rating of switching output DC | 250 mA |
| Short-circuit protection type | timed |
| Short-circuit protection | |
| Overload resistant | |
| Product features |
| Number of inputs and outputs | Number of digital outputs: 1 |
| Process connection | Threaded connection Aseptoflex external thread Aseptoflex |
| Remarks |
| Notes | Please do not use for new projects anymore. No adapters available as accessories. |
| Response times |
| Response time | 1...10 s |
| Software / Programming |
| Switching point adjustment | Push button |
Flow monitor, DC PNP, Connector
Application: hygienic systems
Operating voltage: 19...36 V DC
Process connection: for Aseptoflex adapter
Electrical design: DC PNP
Output function: normally open / closed programmable
Current rating: 250 mA
Liquids:
Medium temperature: -25...95 °C
Setting range: 3...300 cm/s
Greatest sensitivity: 3...100 cm/s
Gases:
Setting range: 200...3000 cm/s
Greatest sensitivity: 200...800 cm/s
Pressure rating: 30 [bar]
Adjustment of the switch point: pushbuttons
Connection: M12 connector
Housing materials: stainless steel 316L / 1.4404; PC (polycarbonate); PBT-GF 20; EPDM/X; O-ring: FKM
Materials (wetted parts): stainless steel 316L / 1.4404; surface characteristics: Ra < 0.4 / Rz 4
Ambient temperature: -25...60 °C
Protection: IP 67 / IP 69K
Accessories (to be ordered separately): Socket, Mounting accessories
Type: SI6200