| Accuracy / Deviations |
| Repeatability | 1...5 cm/s |
| Note on repeatability | For water 5...100 cm/s; 25 °C; factory setting |
| Temperature drift | 0.1; (for water 5...100 cm/s; 10...70 °C) cm/s x 1/K |
| Temperature gradient | 300 K/min |
| Switching point accuracy | ± 2...± 10; (for water 5...100 cm/s; 25 °C; factory setting) cm/s |
| Hysteresis | 2...5; (for water 5...100 cm/s; 25 °C; factory setting) cm/s |
| Approvals / tests |
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-3 |
| Shock resistance | DIN IEC 60068-2-27 / 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6 / 20 g (55...2000 Hz) |
| MTTF | 298 years |
| Displays / controls |
| Indication | Function / 10 x LED, 3-colour |
| Electrical connection |
| Plug connection | 1 x M12; coding: A; contacts: 4 |
| Electrical data |
| Operating voltage | 18...36 DC V |
| Electricity consumption | < 60 mA |
| Protection class | III |
| Standby delay time | 10 s |
| Reverse polarity protection | |
| Environmental conditions |
| Ambient temperature | -25...80 °C |
| Storage temperature | -25...100 °C |
| Degree of protection | IP 65; IP 67 |
| Field of application |
| Media | Liquid media; gaseous media |
| Medium temperature | -25...80 °C |
| Compressive strength | 300 bar / 30 MPa |
| MAWP for applications according to CRN | 208 bar |
| Interfaces |
| Communication interface | IO-Link |
| Transmission type | COM2 (38.4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor - SSP 0 / Generic Profiled Sensor; Function / Device identification; Function / Process data variable |
| Required master port class | A |
| Analog process data | 2 |
| Process data binary | 2 |
| Min. process cycle time | 3 ms |
| Supported DeviceIDs | Operation mode / DeviceID; default / 54 |
| SIO mode | |
| Measurement / adjustment range |
| Rod length L | 45 mm |
| Adjustment range | 3...300 cm/s |
| Maximum sensitivity | 3...100 cm/s |
| Mechanical data |
| Housing | Cylindrical |
| Dimensions | Ø 50 / L = 113 mm |
| Materials | 1.4404 (stainless steel / 316L); 1.4301 (stainless steel / 304); PC; PBT-GF20; EPDM/X |
| Materials in contact with the medium | 1.4404 (stainless steel / 316L); O-ring: FKM 80 Shore A |
| Rod diameter | 8,2 mm |
| Installation length EL | 45 mm |
| Outputs |
| Total number of outputs | 1 |
| Output signal | Switching signal; IO-Link; (configurable) |
| Electrical version | PNP |
| Number of digital outputs | 1 |
| Output function | Normally open contact (NO) / Normally closed contact (NC); (configurable) |
| Max. voltage drop switching output DC | 2,5 V |
| Continuous current rating of switching output DC | 250 mA |
| Short-circuit protection type | timed |
| Short-circuit protection | |
| Overload resistant | |
| Product features |
| Number of inputs and outputs | Number of digital outputs: 1 |
| Process connection | Threaded connection M18 x 1.5 internal thread |
| Response times |
| Response time | 1...10 s |
| Software / Programming |
| Switching point adjustment | Push button |
Flow monitor, Compact type for adapter, DC PNP, Pressure rating: 300 bar, Connector
Application: liquids and gases
Operating voltage: 18...36 V DC
Process connection: internal thread M18 x 1.5 for adapter
Electrical design: DC PNP
Output function: normally open / closed programmable
Current rating: 250 mA
Liquids:
Medium temperature: -25...80 °C
Setting range: 3...300 cm/s
Greatest sensitivity: 3...100 cm/s
Gases:
Setting range: 200...3000 cm/s
Greatest sensitivity: 200...800 cm/s
Pressure rating: 300 [bar]
Adjustment of the switch point: pushbuttons
Connection: M12 connector
Housing materials: stainless steel 316L / 1.4404; stainless steel (304S15); PC (polycarbonate); PBT-GF 20; EPDM/X
Materials (wetted parts): stainless steel 316L / 1.4404; O-ring: FKM 8 x 1.5 gr 80° Shore A
Ambient temperature: -25...80 °C
Protection: IP 65 / IP 67
Accessories (to be ordered separately): Socket, Mounting accessories
Type: SI5010