Further information for ifm Electronic SBG232 flow sensor IO-Link 0,018...0,9 ccm/h
Accuracy / Deviations
Accuracy (within measurement range)
± (4 % MW + 1 % MEW); (Q > 0.3 l/min; medium and ambient temperature: +22 °C ± 4K)
Repeatability
± 1 % MEW
Temperature drift
0,029 °C / K
Accuracy
3 K (25°C; Q > 1 l/min) K
Approvals / tests
EMC
DIN EN 61000-6-2; DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-27 / 20 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 / 5 g (10...2000 Hz)
MTTF
145 years
UL approval
UL certification number / I005; UL file number / E174189
Printer directive
Good engineering practice; suitable for fluids of group 2; fluids of group 1 on request
Displays / controls
Indication
Display unit / 3 x LED, green; Switching state / 2 x LED, yellow; Measured values / alphanumeric display, red / green 4-digit; Programming / alphanumeric display, 4-digit
Electrical connection
Plug connection
1 x M12; Coding: A; Contacts: 4, gold-plated
Electrical data
Operating voltage
18...30 DC; (according to SELV/PELV) V
Electricity consumption
< 50 mA
Protection class
III
Standby delay time
< 3 s
Reverse polarity protection
Environmental conditions
Ambient temperature
0...60 °C
Note on ambient temperature
Medium temperature < 80 °C; Medium temperature < 100 °C: 0...40 °C
Switching signal; Analog signal; Frequency signal; IO-Link; (configurable)
Number of digital outputs
2
Output function
Normally open contact (NO) / Normally closed contact (NC); (configurable)
Max. voltage drop switching output DC
2 V
Continuous current rating of switching output DC
150; (per output 2 x 200 (...60 °C); 2 x 250 (...40 °C)) mA
Switching operations (mechanical)
10 million
Number of analogue outputs
1
Analog output current
4...20 mA
Max. load
500 Ω
Output frequency
0...10000 Hz
Short-circuit protection
Overload resistant
Product features
Number of inputs and outputs
Number of digital outputs: 2; Number of analog outputs: 1
Measuring range
0.3...15 l/min / 0.018...0.9 m³/h
Process connection
Threaded connection G 1/2 internal thread
Remarks
Remarks
Recommendation: use 200-micron filtration. All values apply to water (20 °C). MW = measured value; MEW = end value of measurement range
Notes
Note the changed housing design!
Response times
Response time
0,01 s
Process value damping dAP
0...5 s
Attenuation analog output dAA
0...5 s
Response dynamics T05 / T09
T09 = 120 (Q > 1 l/min) s
Software / Programming
Parameterization options
Hysteresis / window; Normally open contact / normally closed contact; Switching logic; Current/frequency output; Medium selection; Damping for switching/analog output; Rotatable/switchable display; Standard unit of measurement; Process value colour
Mechatronischer Durchflusssensor, Schaltsignal, Analogsignal, Frequenzsignal, IO-Link, Messbereich 0,3...15 l/min, Mediumtemperatur -10...100 °C, Druckfestigkeit 40 bar, G 1/2 Innengewinde, Steckverbindung