Accuracy / Deviations Accuracy (within measurement range) ± 5 % of full scale; (Q > 1 l/min; 20...70 °C medium temperature) Repeatability ± 1 % MEW Temperature drift 0,029 °C / K Accuracy 3 K (25°C; Q > 1 l/min) K Approvals / tests EMC DIN EN 61000-6-2; DIN EN 61000-6-3 Shock resistance DIN EN 60068-2-27 / 20 g (11 ms) Vibration resistance DIN EN 60068-2-6 / 5 g (10...2000 Hz) MTTF 170 years UL approval Approval number UL / I006; File number UL / E174189 Printer directive Good engineering practice Displays / controls Indication Display unit / 6 x LED, green; switching state / 2 x LED, yellow; measured values / alphanumeric display, red/green alternating 4-digit; programming / alphanumeric display, 4-digit Electrical connection Plug connection 1 x M12; Coding: A; Contacts: 4, gold-plated Electrical data Operating voltage 18...30 DC; (according to SELV/PELV; "supply class 2" according to cULus) V Electricity consumption < 50 mA Protection class III Standby delay time < 3 s Reverse polarity protection Yes Environmental conditions Ambient temperature 0...60 °C Note on ambient temperature Medium temperature < 80 °C; Medium temperature < 100 °C: 0...40 °C Storage temperature -15...80 °C Degree of protection IP 65; IP 67 Field of application Special feature Gold-plated contacts Media Liquid media; oils (viscosity 220 mm²/s at 40 °C) Medium temperature -10...100 °C Compressive strength 100 bar / 10 MPa Note on pressure resistance At medium temperature >70°C: 80 bar / 8 MPa MAWP for applications according to CRN 78 bar / 7.8 MPa Interfaces Communication interface IO-Link Transmission type COM2 (38.4 kBaud) IO-Link revision 1.1 SDCI standard IEC 61131-9 CDV Profiles Smart Sensor - SSP 0 / Generic Profiled Sensor; Function / Device identification; Function / Process data variable; Function / Device diagnosis Required master port class A Analog process data 2 Process data binary 2 Min. process cycle time 3,2 ms Supported DeviceIDs Operation mode / DeviceID; default / 1044 SIO mode Yes Measurement / adjustment range Display range 0...30 l/min / 0...1.8 m³/h / 0...475.5 gph / 0...7.93 gpm Resolution 0.01 l/min / 0.001 m³/h / 0.1 gph / 0.001 gpm Switching point SP 0.16...25 l/min / 0.01...1.5 m³/h / 2.5...396 gph / 0.04...6.6 gpm Reverse switch point rP 0...24.84 l/min / 0...1.49 m³/h / 0...393.5 gph / 0...6.56 gpm Frequency endpoint FEP 1.66...25 l/min / 0.1...1.5 m³/h / 26.5...396 gph / 0.44...6.6 gpm Step size 0.02 l/min / 0.002 m³/h / 0.5 gph / 0.01 gpm Frequency at end point FRP 10...10000 Hz Measurement dynamic range 1:50 In steps of 0,1 °C / 0,2 °F Frequency start point FSP -10...78 °C / 14...172,4 °F Mechanical data Materials 1.4404 (stainless steel / 316L); PBT+PC-GF30; PBT-GF20; PC; brass chemically nickel-plated Materials in contact with the medium 1.4401 (stainless steel / 316); 1.4404 (stainless steel / 316L); brass (2.0371); brass, chemically nickel-plated; PPS; O-ring: FKM Mechanical switching cycles 10 million Outputs Total number of outputs 2 Output signal Switching signal; Analog signal; Frequency signal; IO-Link Max. voltage drop switching output DC 2 V Current rating per output 150; (200: ...60 °C; Umgebungstemperatur; 250: ...40 °C; Umgebungstemperatur) mA Analog output current 4...20 mA Max. load 500 Ω Output frequency 0...10000 Hz Short-circuit protection Yes Overload resistant Yes Product features Measuring range 1...25 l/min / 0.06...1.5 m³/h / 16...396.5 gph / 0.26...6.6 gpm Process connection Threaded connection G 1 internal thread Remarks Remarks Recommendation: use 200-micron filtration.; All specifications apply to oil with the following nominal viscosity: 220 mm²/s, 40 °C; MW = measured value; MEW = end value of measurement range Response times Response time 0,01 s Process value damping dAP 0...5 s Attenuation analog output dAA 0...5 s Response dynamics T05 / T09 T09 = 120 (Q > 1 l/min) s Software / Programming Parameterization options Hysteresis / window; Normally open contact (NO) / Normally closed contact (NC); Switching logic; Current / frequency output; Damping switching / analogue output; Rotatable / switchable display; Standard unit of measurement; Process value colour; Calibration factor
Mechatronischer Durchflusssensor, Schaltsignal, Analogsignal, Frequenzsignal, IO-Link, Messbereich 1...25 l/min, Mediumtemperatur -10...100 °C, Druckfestigkeit 100 bar, G 1 Innengewinde, Steckverbindung