Accuracy / Deviations Switching point accuracy < ± 0.5 % of span Repeatability < ± 0.1; (with temperature variations < 10 K) % of span Characteristic deviation < ± 0.25 (BFSL) / < ± 0.5 (LS); (BFSL = Best Fit Straight Line (minimum setting); LS = end-point setting) % of span Hysteresis deviation < ± 0.25 % of span Long-term stability < ± 0.05; (per 6 months) % of span Temperature coefficient zero point 0.2; (-25...80 °C) % of span / 10 K Temperature coefficient range 0.2; (-25...80 °C) % of span / 10 K Approvals / tests EMC DIN EN 61000-6-2; DIN EN 61000-6-3 Shock resistance DIN EN 60068-2-27 / 50 g (11 ms) Vibration resistance DIN EN 60068-2-6 / 20 g (10...2000 Hz) MTTF 256 years UL approval UL certification number / J001 Printer directive Good engineering practice; suitable for fluids of group 2; fluids of group 1 on request Displays / controls Indication display unit / 3 x LED, green (bar, psi, MPa); switching state / 2 x LED, yellow; measured values / alphanumeric display, red / green 4-digit Electrical connection Plug connection 1 x M12; Coding: A; Contacts: 4, gold-plated Electrical data Operating voltage 18...30 DC; (according to SELV/PELV) V Electricity consumption < 35 mA Minimum insulation resistance 100; (500 V DC) MΩ Protection class III Standby delay time < 0,3 s Reverse polarity protection Yes Integrated watchdog Yes Environmental conditions Ambient temperature -25...80 °C Storage temperature -40...100 °C Degree of protection IP 65; IP 67 Field of application Special feature Gold-plated contacts Measuring element Ceramic-capacitive pressure sensor cell Application for industrial use Media Liquid and gaseous media Medium temperature -25...80 °C Min. bursting pressure 150 bar / 2175 psi / 15 MPa Compressive strength 75 bar / 1087 psi / 7.5 MPa Vacuum tightness -1000 mbar Pressure type Gauge pressure Measurement / adjustment range Switching point SP -0.9...10 bar / -13.5...145 psi / -0.09...1 MPa Reverse switch point rP -0.95...9.95 bar / -14...144.5 psi / -0.095...0.995 MPa In steps of 0.05 bar / 0.5 psi / 0.005 MPa Mechanical data Housing Cylindrical Dimensions Ø 34 / L = 90,7 mm Materials 1.4404 (stainless steel / 316L); PBT+PC-GF30; PBT-GF20; PC Materials in contact with the medium 1.4404 (stainless steel / 316L); ceramic; FKM Min. pressure cycles 100 million Tightening moment 25...35; (recommended torque; dependent on lubrication, seal and pressure load) Nm Mechanical switching cycles 100 million Choke element present no (retrofit available) Outputs Total number of outputs 2 Output signal Switching signal Electrical version PNP/NPN Number of digital outputs 2 Output function Normally open contact (NO) / Normally closed contact (NC); (configurable) Max. voltage drop switching output DC 2,5 V Continuous current rating of switching output DC 150; (200 (...60 °C) 250 (...40 °C)) mA Switching frequency DC < 170 Hz Short-circuit protection type timed Short-circuit protection Yes Overload resistant Yes Product features Number of inputs and outputs Number of digital outputs: 2 Measuring range -1...10 bar / -14.5...145 psi / -0.1...1 MPa Process connection threaded connection G 1/4 internal thread Response times Response time < 3 ms Adjustable delay time dS, dr 0...50 s Software / Programming Parameterization options Hysteresis / window; Normally open contact (NO) / Normally closed contact (NC); Switching logic; Switching / reset delay; Damping; Display unit
Elektronischer Druckschalter, -1...10 bar, -14,5...145 psi, -0,1...1 MPa, G 1/4 Innengewinde, Schaltsignal, Steckverbindung, -25...80 °C, IP 65, IP 67, Relativdruck