Accuracy / Deviations Switching point accuracy < ± 0.5 (according to DIN EN 61298-2) % of span Repeatability < ± 0.05; (with temperature variations < 10 K) % of span Characteristic deviation < ± 0.5; (linearity including hysteresis and repeatability, end-point setting according to DIN EN IEC 62828-1) % of span Linearity deviation < ± 0.1 (BFSL) / < ± 0.2 (LS) % of span Neutral point stabilisation IO-Link / 1.0; (See operating manual for zero point behavior); Switching output / 1.0 % of range Hysteresis deviation < ± 0.2 % of span Long-term stability < ± 0.1; (per 6 months) % of span Temperature coefficient zero point < 0.1 (-25...90 °C) / < 0.2 (-40...-25 °C) % of span / 10 K Temperature coefficient range < 0.1 (-25...90 °C) / < 0.2 (-40...-25 °C) % of span / 10 K Approvals / tests EMC DIN EN 61326-1 Shock resistance DIN EN 60068-2-27 / 500 g (1 ms) Vibration resistance DIN EN 60068-2-6 / 20 g (10...2000 Hz) MTTF 668 years UL approval UL approval number / J015 Printer directive Good engineering practice; suitable for fluids of group 2; fluids of group 1 on request Electrical connection Plug connection 1 x M12; coding: A; contacts: 4 Electrical data Operating voltage 18...30 DC V Electricity consumption < 15 mA Minimum insulation resistance 100; (500 V DC) MΩ Protection class III Standby delay time < 0,3 s Reverse polarity protection Yes Environmental conditions Ambient temperature -40...90 °C Storage temperature -40...100 °C Degree of protection IP 67; IP 69K Field of application Measuring element metallic thin-film cell Application for industrial use Media Liquid and gaseous media Medium temperature -40...90 °C Min. bursting pressure 60 MPa Compressive strength 6.5 MPa Note on pressure resistance Static Vacuum tightness -1000 mbar / -0.1 MPa Pressure type Relative pressure; vacuum Interfaces Communication interface IO-Link Transmission type COM2 (38.4 kBaud) IO-Link revision 1.1 SDCI standard IEC 61131-9 Profiles Smart Sensor - SSP 0 / Generic Profiled Sensor; Function / Device identification; Function / Process data variable; Function / Device diagnosis Required master port class A Min. process cycle time 5 ms Supported DeviceIDs Operation mode / DeviceID; default / 783 SIO mode Yes Measurement / adjustment range Switching point SP -0.075...2.5 MPa Reverse switch point rP -0.087...2.488 MPa In steps of 0.001 MPa Factory setting SP1 = 0.625 MPa / rP1 = 0.575 MPa / ou1 = Hno;; SP2 = 1.875 MPa / rP2 = 1.825 MPa / ou2 = Hno;; dS1/dS2 = 0 ms / dr1/dr2 = 0 ms; coF = 0 % / P-n = PnP / dAP= 60 ms Mechanical data Housing Cylindrical Dimensions Ø 19 / L = 67 mm Materials 1.4542 (stainless steel / 17-4 PH / 630); 1.4404 (stainless steel / 316L); PEI Materials in contact with the medium 1.4305 (Stainless steel / 303); 1.4542 (Stainless steel / 17-4 PH / 630) Min. pressure cycles 60 million; (at 1.2 times rated pressure) Tightening moment 50; (recommended torque; dependent on lubrication, sealing and pressure load) Nm Choke element present Yes Outputs Total number of outputs 2 Output signal Switching signal; IO-Link; (configurable) Electrical version PNP/NPN Number of digital outputs 2 Output function Normally open contact (NO) / Normally closed contact (NC); (configurable) Max. voltage drop switching output DC 2 V Continuous current rating of switching output DC 100 mA Switching frequency DC < 170 Hz Short-circuit protection type timed Short-circuit protection Yes Overload resistant Yes Product features Number of inputs and outputs Number of digital outputs: 2 Measuring range -0.1...2.5 MPa Process connection Threaded connection R 1/4 external thread internal thread: M5 Remarks Remarks BFSL = Best Fit Straight Line (minimum setting); LS = limit point setting Response times Response time < 3 ms Software / Programming Parameterization options Hysteresis / window; Normally open contact (NO) / Normally closed contact (NC); Switching logic; Switching / reset delay; Damping
Elektronischer Druckschalter, -0,1...2,5 MPa, R 1/4 Außengewinde, Schaltsignal, IO-Link, Steckverbindung, -40...90 °C, IP 67, IP 69K, Relativdruck, Vakuum