Further information for ifm Electronic PT3540 pressure sensor 0...400 bar G 1/4
Accuracy / Deviations
Repeatability
< ± 0.1; (with temperature variations < 10 K) % of span
Characteristic deviation
< ± 1.0; (including screw-in drift, zero point and span error) % of span
Linearity deviation
< ± 0.25 (BFSL) / < ± 0.5 (LS) % of span
Hysteresis deviation
< ± 0.2 % of span
Long-term stability
< ± 0.1; (per 6 months) % of span
Temperature coefficient zero point
< ± 0.1; (-25...90 °C) % of span / 10 K
Temperature coefficient range
< ± 0.1; (-25...90 °C) % of span / 10 K
Approvals / tests
EMC
EN 61000-4-2 ESD / 4 kV CD / 8 kV AD; EN 61000-4-3 Radiated HF / 10 V/m; EN 61000-4-4 Burst / 4 kV coupling clamp; EN 61000-4-5 Surge / 1 kV signal for DC devices; EN 61000-4-6 Conducted HF / 10 V
Shock resistance
DIN IEC 68-2-27 / 50 g (11 ms)
Vibration resistance
DIN IEC 68-2-6 / 20 g (10...2000 Hz)
MTTF
1579 years
Printer directive
Good engineering practice; suitable for fluids of group 2; fluids of group 1 on request
Electrical connection
Plug connection
1 x M12; coding: A; contacts: 4
Electrical data
Operating voltage
8,5...36 DC V
Minimum insulation resistance
100; (500 V DC) MΩ
Protection class
III
Reverse polarity protection
Environmental conditions
Ambient temperature
-25...90 °C
Storage temperature
-40...100 °C
Degree of protection
IP 67; IP 69K
Field of application
Application
for industrial use
Media
Liquid and gaseous media
Medium temperature
-25...90 °C
Min. bursting pressure
1600 bar / 23200 psi / 160 MPa
Compressive strength
600 bar / 8700 psi / 60 MPa
Pressure type
Gauge pressure
Mechanical data
Housing
Cylindrical
Dimensions
Ø 22 / L = 65,1 mm
Materials
1.4404 (stainless steel / 316L); PA
Materials in contact with the medium
1.4404 (Stainless steel / 316L); Seal: FKM
Min. pressure cycles
50 million
Choke element present
no (retrofit available)
Outputs
Total number of outputs
1
Output signal
Analog signal
Number of analogue outputs
1
Analog output current
4...20 mA
Max. load
775; (Ub = 24 V; (Ub - 8,5 V) / 20 mA) Ω
Product features
Number of inputs and outputs
Number of analog outputs: 1
Measuring range
0...400 bar / 0...5800 psi / 0...40 MPa
Process connection
Threaded connection G 1/4 male thread
Remarks
Remarks
BFSL = Best Fit Straight Line (minimum setting); LS = limit point setting
Response times
Step response time analog output
3 ms
Elektronischer Drucksensor, 0...400 bar, 0...5800 psi, 0...40 MPa, G 1/4 Außengewinde, Analogsignal, 4...20 mA, Steckverbindung, -25...90 °C, IP 67, IP 69K, Relativdruck