Further information for ifm Electronic PQC812 pressure sensor for pneumatics
Accessories
Scope of delivery
Cylinder screw: 2 x (M3 x 8 mm)
Accuracy / Deviations
Switching point accuracy
< ± 0.5; (Turn down 1:1) % of span
Repeatability
< ± 0.1; (with temperature variations < 10 K: turn down 1:1) % of span
Characteristic deviation
< ± 0.5; (turn down 1:1; including linearity, hysteresis and repeatability) % of span
Linearity deviation
< ± 0.5 % (limit point setting according to DIN EN IEC 62828-1) Turn down 1:1 % of span
Hysteresis deviation
< ± 0.25; (turn down 1:1) % of span
Long-term stability
< ± 0.1; (turn down 1:1; per year) % of span
Temperature coefficient zero point
0.2; (turn down 1:1) % of span / 10 K
Temperature coefficient range
0.2; (turn down 1:1) % of span / 10 K
Approvals / tests
EMC
DIN EN 61326-1
Shock resistance
DIN EN 60068-2-27 / 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 / 20 g (10...2000 Hz)
MTTF
411 years
UL approval
Approval number UL / J067; File number UL / E174189
Printer directive
Good engineering practice; suitable for stable gases of fluid group 2
Displays / controls
Indication
Display 1" / 128 x 96 pixels; Switching state / 1 x LED, yellow
Display unit
bar; MPa; mmHg; kgf/cm²
Electrical connection
Plug connection
1 x M8; coding: A; contacts: 4, gold-plated
Electrical data
Operating voltage
18...30 DC V
Electricity consumption
< 30 mA
Minimum insulation resistance
100; (500 V DC) MΩ
Protection class
III
Standby delay time
0,3 s
Reverse polarity protection
Integrated watchdog
Environmental conditions
Ambient temperature
0...60 °C
Storage temperature
-25...85 °C
Degree of protection
IP 65
Field of application
Special feature
Gold-plated contacts
Application
for industrial use
Media
Compressed air; nitrogen (N2)
Conditionally suitable for
Other media available on request
Medium temperature
0...60 °C
Min. bursting pressure
20 bar / 2 MPa
Compressive strength
15 bar / 1.5 MPa
Vacuum tightness
-1000 mbar / -0.1 MPa
Pressure type
Relative pressure; vacuum
Interfaces
Communication interface
IO-Link
Transmission type
COM3 (230.4 kBaud)
IO-Link revision
1.1.3
SDCI standard
IEC 61131-9: 2019-06
Profiles
Smart Sensor - SSP 4.1.1 / Measuring and Switching Sensor, 1 channel; BLOB / Binary Large Object transfer; Common - I&D / Identification and Diagnosis; Extension / Quantity detection, switches when value exceeds the setpoint; Function / Locator; Function / ProductURI
Required master port class
A
Analog process data
1
Process data binary
2
Min. process cycle time
0,6 ms
IO-Link pressure resolution
0.001 bar
IO-Link process data (cyclic)
function / bit length; pressure / 16; device status / 4; SSC1.1 / 1; SSC1.2 / 1
IO-Link functions (asynchronous)
Application-specific marking; internal temperature; medium temperature
Supported DeviceIDs
Operating mode / DeviceID; default / 1580
SIO mode
Measurement / adjustment range
Switching point SP
-1...10 bar / -0.1...1 MPa
Analog start point
-1...8 bar / -0.1...0.8 MPa
Analog endpoint
1...10 bar / 0.1...1 MPa
In steps of
0.01 bar / 0.001 MPa
Mechanical data
Housing
rectangular
Dimensions
37,7 x 30 x 38,6 mm
Materials
PBT; PC; TPE; NBR; FKM; Brass; Silicon (coated)
Materials in contact with the medium
PBT; FKM; Brass; Silicon (coated)
Min. pressure cycles
50 million
Outputs
Total number of outputs
2
Output signal
Switching signal; analog signal; IO-Link; (configurable)
Electrical version
PNP/NPN; (configurable)
Number of digital outputs
1
Output function
Normally open contact (NO) / Normally closed contact (NC); (configurable)
Max. voltage drop switching output DC
2,5 V
Continuous current rating of switching output DC
100 mA
Switching frequency DC
< 170 Hz
Number of analogue outputs
1
Analog output current
4...20, reversible; (scalable) mA
Max. load
500 Ω
Analog output voltage
0...10 / 1...5, invertible; (scalable) V
Minimum load resistance
2000 Ω
Short-circuit protection type
timed
Short-circuit protection
Overload resistant
Product features
Number of inputs and outputs
Number of digital outputs: 1; Number of analog outputs: 1
Measuring range
-1...10 bar / -0.1...1 MPa
Process connection
Threaded connection G 1/8 internal thread (2x)
Response times
Response time
6 ms
Process value damping dAP
0...4 s
Attenuation analog output dAA
0...99,99 s
Software / Programming
Parameterization options
Rotatable/shutoff display; switchable and scalable analog output; teach function; simulation function; diagnosis function