| Accuracy / Deviations |
| Switching point accuracy | < ± 0.5 % of span |
| Repeatability | < ± 0.1; (with temperature variations < 10 K) % of span |
| Characteristic deviation | < ± 0.25 (BFSL) / < ± 0.5 (LS); (BFSL = Best Fit Straight Line (minimum setting); LS = end-point setting) % of span |
| Hysteresis deviation | < ± 0.25 % of span |
| Long-term stability | < ± 0.05; (per 6 months) % of span |
| Temperature coefficient zero point | 0.2; (0...60 °C) % of range / 10 K |
| Temperature coefficient range | 0.2; (0...60 °C) % of range / 10 K |
| Approvals / tests |
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-3 |
| Shock resistance | DIN EN 60068-2-27 / 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6 / 20 g (10...2000 Hz) |
| MTTF | 437 years |
| Printer directive | Good engineering practice; suitable for fluids of group 2; fluids of group 1 on request |
| Displays / controls |
| Indication | Display unit / 4 x LED, green; Switching state / 1 x LED, yellow; Function indicator / alphanumeric display, 4-digit; Measured values / alphanumeric display, 4-digit |
| Display unit | bar; kPa; psi; inHg |
| Electrical connection |
| Plug connection | 1 x M8; coding: A; contacts: 4, gold-plated |
| Electrical data |
| Operating voltage | 18...32 DC; (according to SELV/PELV) V |
| Electricity consumption | < 50 mA |
| Minimum insulation resistance | 100; (500 V DC) MΩ |
| Protection class | III |
| Standby delay time | 0,5 s |
| Reverse polarity protection | |
| Integrated watchdog | |
| Environmental conditions |
| Ambient temperature | 0...70 °C |
| Storage temperature | -25...85 °C |
| Degree of protection | IP 65 |
| Field of application |
| Special feature | Gold-plated contacts |
| Application | for industrial use |
| Conditionally suitable for | Other media available on request |
| Medium temperature | 0...60 °C |
| Min. bursting pressure | 30 bar / 435 psi / 886 inHg / 3000 kPa |
| Note on minimum burst pressure | Max. overpressure on second pressure connection: 12 bar / 1200 kPa / 174 PSI / 354.4 inHg / 1.2 MPa |
| Compressive strength | 20 bar / 290 psi / 591 inHg / 2000 kPa |
| Vacuum tightness | -1000 mbar / -0.1 MPa |
| Pressure type | Gauge pressure; Differential pressure; Vacuum |
| Interfaces |
| Communication interface | IO-Link |
| Transmission type | COM2 (38.4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 FDIS |
| Profiles | Smart Sensor - SSP 0 / Generic Profiled Sensor; Function / Device identification; Function / Process data variable |
| Required master port class | A |
| Analog process data | 1 |
| Process data binary | 2 |
| Min. process cycle time | 2,3 ms |
| Supported DeviceIDs | Operating mode / DeviceID; default / 367 |
| SIO mode | |
| Measurement / adjustment range |
| Switching point SP | -0.9...10 bar / -13...145 psi / -26...296 inHg / -90...1000 kPa |
| Reverse switch point rP | -0.95...9.95 bar / -14...144 psi / -28...294 inHg / -95...995 kPa |
| In steps of | 0.05 bar / 1 psi / 2 inHg / 5 kPa |
| Mechanical data |
| Housing | rectangular |
| Dimensions | 42 x 30 x 32 mm |
| Materials | PBT; FKM; polyester |
| Materials in contact with the medium | Brass; FKM; Silicon (coated); PBT |
| Min. pressure cycles | 50 million |
| Outputs |
| Total number of outputs | 2 |
| Output signal | Switching signal; analog signal; IO-Link; (configurable) |
| Electrical version | PNP |
| Number of digital outputs | 1 |
| Output function | Normally open contact (NO) / Normally closed contact (NC); (configurable) |
| Max. voltage drop switching output DC | 2 V |
| Continuous current rating of switching output DC | 100 mA |
| Switching frequency DC | < 100 Hz |
| Number of analogue outputs | 1 |
| Analog output current | 4...20 mA |
| Max. load | 500 Ω |
| Short-circuit protection type | timed |
| Short-circuit protection | |
| Product features |
| Number of inputs and outputs | Number of digital outputs: 1; Number of analog outputs: 1 |
| Measuring range | -1...10 bar / -15...145 psi / -30...296 inHg / -100...1000 kPa |
| Process connection | Threaded connection G 1/8 female thread female thread:M5 |
| Response times |
| Response time | < 6 ms |
| Adjustable delay time dS, dr | 0; 0,002...5 s |
| Step response time analog output | 6 ms |
| Software / Programming |
| Parameterization options | Hysteresis / window; normally open contact (NO) / normally closed contact (NC); analogue output; IO-Link; switching logic; ramp-up/ramp-down delay; damping; display unit |
Electronic pressure sensor, DC PNP, Function programmable, 4-digit alphanumeric display, 2 outputs, OUT1 = switching output, IO-Link, OUT2 = analogue output, 4-digit alphanumeric display
Application: Type of pressure: relative pressure, differential pressure, compressed air *
Measuring range: -1.00...10.00 bar; -100...1000 kPa; -15...145 psi; -30...296 inHg
Display: Display unit: 4 x LED green ; Switching status: 1 x LED yellow ; Function display: 4-digit alphanumeric display ; Measured values: 4-digit alphanumeric display