| Accessories |
| Scope of delivery | Connection cable: 0.8 m, for parameterization in offline operation |
| Approvals / tests |
| EMC | EN 61000-4-2 ESD / 4 kV CD / 8 kV AD; EN 61000-4-3 Radiated HF / 10 V/m; EN 61000-4-4 Burst / 2 kV; EN 61000-4-6 Conducted HF / 10 V |
| Shock resistance | DIN IEC 68-2-27 / 50 g (11 ms) |
| Vibration resistance | DIN IEC 68-2-6 / 20 g (10...2000 Hz) |
| MTTF | 229 years |
| Displays / controls |
| Indication | Display unit / 6 x LED, green; switching state / 2 x LED, yellow; function indication / alphanumeric display, 4-digit; measured values / alphanumeric display, 4-digit |
| Electrical connection |
| Plug connection | 1 x M12; Contacts: gold-plated |
| Electrical data |
| Operating voltage | 18...32 DC V |
| Electricity consumption | < 40 mA |
| Minimum insulation resistance | 100; (500 V DC) MΩ |
| Protection class | III |
| Standby delay time | 1.5...10; (depending on connected sensor) s |
| Reverse polarity protection | |
| Environmental conditions |
| Ambient temperature | -25...80 °C |
| Storage temperature | -40...100 °C |
| Degree of protection | IP 67; (for device with screwed-in connectors) |
| Field of application |
| Special feature | Gold-plated contacts |
| Application | for industrial use |
| Mechanical data |
| Dimensions | 100 x 34 x 48 mm |
| Materials | 1.4404 (stainless steel / 316L); CO-PC; PBT; FKM |
| Outputs |
| Max. voltage drop switching output DC | 2 V |
| Continuous current rating of switching output DC | 250 mA |
| Short-circuit protection type | timed |
| Short-circuit protection | |
| Overload resistant | |
| Response times |
| Max. measurement/display cycle time | 200 ms |
| Software / Programming |
| Parameterization options | dependent on connected sensor |
Programmier-/Anzeigegerät, 100 x 34 x 48 mm, Steckverbindung, Zulassung, cULus, UKCA