| Accuracy / Deviations |
| Characteristic deviation | < ± 0.6 % of end value |
| Temperature influence per 10 K | < ± 0,3 |
| Analog input characteristic deviation | < ± 0,3 |
| Temperature influence analog input per 10 K | < ± 0,1 |
| Temperature influence on analogue input | 0...80 °C |
| Approvals / tests |
| EMC | EN 61000-4-2 ESD / 4 kV CD / 8 kV AD; EN 61000-4-3 Radiated HF / 10 V/m; EN 61000-4-4 Burst / 2 kV; EN 61000-4-6 Conducted HF / 10 V |
| Shock resistance | DIN IEC 68-2-27 / 50 g (11 ms) |
| Vibration resistance | DIN IEC 68-2-6 / 20 g (10...2000 Hz) |
| MTTF | 152 years |
| Printer directive | Good engineering practice; suitable for fluids of group 2; fluids of group 1 on request |
| Displays / controls |
| Indication | Display unit / 3 x LED, green; Display mode / 3 x LED, green; Switching state / 2 x LED, yellow; Function indication / alphanumeric display, 4-digit; Measured values / alphanumeric display, 4-digit |
| Display unit | bar; psi; MPa |
| Electrical connection |
| Plug connection | 1 x M12; Coding: A; Contacts: 7, gold-plated |
| Electrical data |
| Operating voltage | 18...30 DC V |
| Electricity consumption | < 90 mA |
| Minimum insulation resistance | 100; (500 V DC) MΩ |
| Protection class | III |
| Standby delay time | 0,2 s |
| Reverse polarity protection | |
| Integrated watchdog | |
| Environmental conditions |
| Ambient temperature | -25...80 °C |
| Storage temperature | -40...100 °C |
| Degree of protection | IP 67 |
| Field of application |
| Special feature | Gold-plated contacts |
| Application | for industrial use |
| Media | Liquid and gaseous media |
| Conditionally suitable for | Use in gaseous media at pressures > 25 bar only on request |
| Medium temperature | -25...80 °C |
| Min. bursting pressure | 850 bar / 85 MPa |
| Compressive strength | 400 bar / 40 MPa |
| Pressure type | Gauge pressure |
| Inputs |
| Analogue input current | 0...20 mA |
| Input impedance | 300 Ω |
| Analogue input voltage | 0...10 V |
| Measurement / adjustment range |
| Switching point SP | -62...250 bar |
| Switching point SP note | Differential pressure |
| Reverse switch point rP | -63...249 bar |
| Note on reverse switching point rP | Differential pressure |
| In steps of | 1 bar |
| Mechanical data |
| Housing | Cylindrical |
| Dimensions | Ø 34 / L = 91,5 mm |
| Materials | 1.4305 (stainless steel / 303); PBT; PC; PA; FKM |
| Materials in contact with the medium | 1.4305 (stainless steel / 303); ceramic; FKM |
| Min. pressure cycles | 100 million |
| Choke element present | no (retrofit available) |
| Outputs |
| Total number of outputs | 2 |
| Output signal | Switching signal |
| Electrical version | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | Normally open contact (NO) / Normally closed contact (NC); (configurable) |
| Max. voltage drop switching output DC | 2 V |
| Continuous current rating of switching output DC | 250 mA |
| Switching frequency DC | < 170 Hz |
| Short-circuit protection type | timed |
| Short-circuit protection | |
| Overload resistant | |
| Product features |
| Number of inputs and outputs | Number of digital outputs: 2 |
| Measuring range | 0...250 bar |
| Process connection | threaded connection G 1/4 internal thread |
| Response times |
| Response time | < 3 ms |
| Adjustable delay time dS, dr | 0, 0,1...50 s |
| Process value damping dAP | 0...4 s |
| Software / Programming |
| Switching point adjustment | Programming button |
| Parameterization options | Hysteresis / window; normally open contact (NO) / normally closed contact (NC); switching logic; current/voltage input; damping; display value adjustment; rotatable / switchable display; display unit |
Electronic pressure switch, 0...250 bar, G 1/4 internal thread, switching signal, plug connection, -25...80 °C, IP 67, relative pressure