Accuracy / Deviations Switching point accuracy < ± 0.5 % of span Repeatability < ± 0.1; (with temperature variations < 10 K) % of span Characteristic deviation < ± 0.25 (BFSL) / < ± 0.5 (LS); (BFSL = Best Fit Straight Line (minimum setting); LS = end-point setting) % of span Hysteresis deviation < ± 0.25 % of span Long-term stability < ± 0.05; (per 6 months) % of span Temperature coefficient zero point < ± 0.2; (-0...80 °C) % of span / 10 K Temperature coefficient range < ± 0.2; (-0...80 °C) % of span / 10 K Approvals / tests EMC DIN EN 61000-6-2; DIN EN 61000-6-3 Shock resistance DIN EN 60068-2-27 / 50 g (11 ms) Vibration resistance DIN EN 60068-2-6 / 20 g (10...2000 Hz) MTTF 260 years UL approval UL certification number / J001 Printer directive Good engineering practice; suitable for fluids of group 2; fluids of group 1 on request Displays / controls Indication Display unit / 3 x LED, green (bar, psi, kPa); Switching state / 2 x LED, yellow; Measured values / alphanumeric display, red / green 4-digit Electrical connection Plug connection 1 x M12; Coding: A; Contacts: 4, gold-plated Electrical data Operating voltage 18...30 DC; (according to SELV/PELV) V Electricity consumption < 35 mA Minimum insulation resistance 100; (500 V DC) MΩ Protection class III Standby delay time < 0,3 s Reverse polarity protection Yes Integrated watchdog Yes Environmental conditions Ambient temperature -25...80 °C Storage temperature -40...100 °C Degree of protection IP 65; IP 67 Field of application Special feature Gold-plated contacts Measuring element Ceramic-capacitive pressure sensor cell Application for industrial use Media Liquid and gaseous media Medium temperature -25...80 °C Min. bursting pressure 50 bar / 725 psi / 5000 kPa Compressive strength 20 bar / 290 psi / 2000 kPa Vacuum tightness -1000 mbar / -0.1 MPa Pressure type Gauge pressure Interfaces Communication interface IO-Link Transmission type COM2 (38.4 kBaud) IO-Link revision 1.1 SDCI standard IEC 61131-9 Required master port class A; (if PIN 2 not connected: B) Analog process data 1 Process data binary 2 Supported DeviceIDs Operation mode / DeviceID; Factory setting / CMPT = 2 / 404; Status_B High Resolution / CMPT = 3 / 602 Note Further information can be found in the IODD-PDF file under "Downloads" Profiles Smart Sensor - SSP 0 / Generic Profiled Sensor; Function / Device identification; Function / Process data variable; Function / Device diagnosis Min. process cycle time 2,3 ms IO-Link pressure resolution 0.01 bar / 0.001 MPa IO-Link process data (cyclic) Function / bit length; pressure / 14; binary switching information / 2 IO-Link functions (asynchronous) Application-specific marking SIO mode Yes Measurement / adjustment range Switching point SP 0.02...2.5 bar / 0.4...36.2 psi / 2...250 kPa Reverse switch point rP 0.01...2.49 bar / 0.2...36 psi / 1...249 kPa Min. distance between SP and rP 0.02 bar / 0.2 psi / 2 kPa In steps of 0.01 bar / 0.2 psi / 1 kPa Mechanical data Materials 1.4404 (stainless steel / 316L); PBT+PC-GF30; PBT-GF20; PC Materials in contact with the medium 1.4404 (stainless steel / 316L); ceramic; FKM Min. pressure cycles 100 million Tightening moment 25...35; (recommended torque; dependent on lubrication, seal and pressure load) Nm Choke element present no (retrofit available) Outputs Total number of outputs 2 Output signal Switching signal; IO-Link; (configurable) Electrical version PNP/NPN Number of digital outputs 2 Output function Normally open contact (NO) / Normally closed contact (NC); (configurable) Max. voltage drop switching output DC 2,5 V Continuous current rating of switching output DC 150; (200 (...60 °C) 250 (...40 °C)) mA Switching frequency DC < 170 Hz Short-circuit protection type timed Short-circuit protection Yes Overload resistant Yes Product features Number of inputs and outputs Number of digital outputs: 2 Measuring range 0...2.5 bar / 0...2500 mbar / 0...36.2 psi / 0...250 kPa Process connection Threaded connection G 1/4 male thread; Internal thread: M5 Response times Response time < 3 ms Adjustable delay time dS, dr 0...50 s Software / Programming Parameterization options Hysteresis / window; Normally open contact (NO) / Normally closed contact (NC); Switching logic; Switching / reset delay; Damping; Display unit
Elektronischer Druckschalter, 0...2,5 bar, 0...2500 mbar, 0...36,2 psi, 0...250 kpa, G 1/4 Außengewinde, Schaltsignal, IO-Link, Steckverbindung, -25...80 °C, IP 65, IP 67, Relativdruck